background image

iv 

©2010 Enerdrive Pty Ltd

Содержание MagnaSine ME-BMK

Страница 1: ...ME BMK Battery Monitor Kit Owner s Manual...

Страница 2: ...ral electrical codes This product is designed for indoor compartment installation It must not be exposed to rain snow moisture or liquids of any type Use insulated tools to reduce the chance of electr...

Страница 3: ...1 ME BMK Installation Diagram 4 Figure 2 2 DC Shunt Connections 5 Figure 2 3 Sense Module Connections 6 Figure 2 4 Multiple Network Devices Star Configuration 7 Figure 2 5 Multiple Network Devices Dai...

Страница 4: ...iv 2010 Enerdrive Pty Ltd...

Страница 5: ...ut voltage Temperature and battery bank capacity automatically compensated and coordinated between inverter and battery monitor Precision 500A 50mv DC shunt included in ME BMK Automatic efficiency det...

Страница 6: ...te is easily displayed but doesn t provide an accurate State Of Charge under all charge and discharge conditions Theses devices have advantages and disadvantages based on accuracy and ease of use The...

Страница 7: ...nnecting any wires determine 1 the commu nications cable route throughout the home or vehicle boat to the inverter and 2 the twisted pair signal wire route to the ME BMK shunt Info The communications...

Страница 8: ...4 2010 Enerdrive Pty Ltd Installation Figure 2 1 ME BMK Installation Diagram...

Страница 9: ...s is not possible adequate forced ventilation should be provided to keep the shunt operat ing temperature below 60 C CAUTION Before beginning the installation ensure all AC power is dis connected from...

Страница 10: ...connection 2 connect the orange wire from the 2 terminal on the 4 port terminal block to the small screw on the load side of the shunt positive shunt sense connection Info Ensure these blue and orange...

Страница 11: ...network port via a phone splitter to the inverter using individual cable runs see figure 2 4 Since each device is independently connected to the inverter s MagnaSine Net or network port problems in a...

Страница 12: ...batteries inefficiencies while charging a charge efficiency setting is provided The charge efficiency setting compensates the AH I O AmpHrs In Out reading by ensuring the amphrs returned to the bat t...

Страница 13: ...would be more inaccurate with every charge For this reason continually monitor the AH I O reading under the 03 BM Meters menu After several charge and discharge cycles below 80 SOC the AH I O reading...

Страница 14: ...Map ME BMK Displays 4 0 METER Menu Map The following figure is a complete overview of the battery monitor settings and information displays available under the METER menu for the ME BMK Familiarize yo...

Страница 15: ...nergy loses while charging and is one of the factors used to determine the battery s State Of Charge SOC The battery s State of Charge which is the best indicator of the condition of the batteries is...

Страница 16: ...the connected battery bank The SOC represents the condition of the battery as a percentage of the avail able capacity left in the battery Range is 0 to 100 where 100 represents a fully charged batter...

Страница 17: ...displayed value resets to zero Info The AH I O display correlates with the 03 Batt AmpHr setting under the SETUP button to help determine the 02 BM SOC display Info AH I O example if you run a 10 amp...

Страница 18: ...mine the issue BM Ready The BM is connected and actively monitoring the battery system 05 BM SETUP This menu allows the battery s charging efficiency to be automati cally determined or manually select...

Страница 19: ...Figure 5 6 Resetting the Max DC Value Figure 5 5 Resetting the Min DC Value Max DC This menu displays the highest battery voltage since the last reset The voltage shown on the display is averaged each...

Страница 20: ...transmitting and receiving correctly with network devices Green BLINKING Not able to communicate with remote display A If the remote display is off refer to the remote s operation manual for troubles...

Страница 21: ...ding is incorrect Measure the voltage between the red terminal 4 positive and black terminal 3 negative wire on the terminal block in the sense module If the voltage at the Sense module and the voltag...

Страница 22: ...AH increments tAH Out Total Amp Hours Removed 0 to 65 535 000 amp hours 0 1k or 100 AH increments Min Max DC 7 00 to 70 00 VDC resettable Shipping Weight 2 lbs Includes Manual Sense Module DC shunt tw...

Страница 23: ...at the time the original purchaser returns the product for repair determined by the price paid by the original purchaser Enerdrive shall not be liable for any other losses or damages 4 Upon request fr...

Страница 24: ...PN 64 0013 MagnaSine by Enerdrive Unit 11 1029 Manly Road Tingalpa Queensland Australia 4173 Ph 1300 851 535 email sales enerdrive com au www enerdrive com au...

Отзывы: