7. Warranty

24 Month Limited Warranty

Enerdrive warrants the ME Series Auto Gen Start to be free from defects in material 

and workmanship that result in product failure during normal usage, according to 

the following terms and conditions:

1.  The limited warranty for the product extends for 24 months beginning from 

the product’s original date of purchase.

2.  The limited warranty extends to the original purchaser of the product and is 

not assignable or transferable to any subsequent purchaser.

3.  During the limited warranty period, Enerdrive will repair, or replace at 

Enerdrive’s option, any defective parts, or any parts that will not properly 

operate for their intended use with factory new or rebuilt replacement items 

if such repair or replacement is needed because of product malfunction or 

failure during normal usage. The limited warranty does not cover defects in 

appearance, cosmetic, decorative or structural parts or any non-operative 

parts. Enerdrive’s limit of liability under the limited warranty shall be the 

actual cash value of the product at the time the original purchaser returns 

the product for repair, determined by the price paid by the original purchaser. 

Enerdrive shall not be liable for anyother losses or damages.

4.  Upon request from Enerdrive, the original purchaser must prove the product’s 

original date of purchase by a dated bill of sale, itemized receipt.

5.  The original purchaser shall return the product prepaid to Enerdrive. 

Enerdrive will return the product prepaid to the original purchaser after the 

completion of service under this limited warranty.

6.  This limited warranty is voided if:

•  the product has been modified without authorization

•  the serial number has been altered or removed

•  the product has been damaged through abuse, neglect, accident, 

high voltage or corrosion.

•  the product was not installed and operated according to the 

owner’s manual.

IN CASE OF WARRANTY FAILURE, CONTACT ENERDRIVE FOR A RETURN 

AUTHORIZATION (RA) NUMBER BEFORE RETURNING THE UNIT FOR REPAIR.

MagnaSine by Enerdrive

Unit 10, 1029 Manly Road Tingalpa,

Queensland, Australia 4173

Ph: 1300 851 535

Содержание MagnaSine ME AGS

Страница 1: ...ME AGS Auto Gen Start Network System with Inverter and Remote for Coach Generators Operator s Manual...

Страница 2: ...2 2010 Enerdrive Pty Ltd...

Страница 3: ...ystem with Inverter and Remote for Coach Generators Table of Contents SAVE THESE INSTRUCTIONS This manual contains important safety instructions Section 1 Overview 2 Configuration 3 Installation 4 Ope...

Страница 4: ...n the inside temperature of the coach or a low battery condition These features allow you to leave pets and precious items in your coach while you enjoy a day away golfing touring or just sight seeing...

Страница 5: ...Diesel generators the controller is configured with the Diesel Petrol jumper positioned over the two left hand pins as shown below factory default For most petrol as well as other diesel generators yo...

Страница 6: ...ith version 0 5 or higher version 0 5 or higher REMOTE Stand alone switch Stand alone switch PORT pigtail direct to a c thermostat pigtail direct to a c thermostat or sensor only or sensor only START...

Страница 7: ...leshooting Wiring is much easier if the controller is mounted within easy access to the generator s remote wiring Pre drill the four 1 8 holes if necessary 2 Remove the 8 pin connector from the contro...

Страница 8: ...best results NOTE The thermistor that is used to sense the coach s interior temperature is located on the back of the AGS Switch It is vital that the switch be placed where interior room temperatures...

Страница 9: ...re interior room temperatures can be accurately monitored by the thermistor Keep the switch away from heating and air conditioning ducts window drafts and avoid mounting it on the coach s exterior wal...

Страница 10: ...10 2010 Enerdrive Pty Ltd 3 Installation Figure 3 AGS Wiring Diagram...

Страница 11: ...2010 Enerdrive Pty Ltd 11 3 Installation Figure 4 AGS Connector Pin Legend from left to right...

Страница 12: ...tage setting is reached NOTE To change this setting slowly rotate the knob marked START VOLTS clockwise to increase the voltage or counterclockwise to decrease voltage The range is 10 VDC to 12 VDC NO...

Страница 13: ...evening and early morning It is adjustable for five pre selected time ranges To set quiet time turn the dial either counter clockwise or clockwise to the hours required 9 7 9 PM to 7 AM 9 8 9 PM to 8...

Страница 14: ...temperature or low battery voltage conditions Temperature and voltage settings are selected using the AGS Controller page 11 AutoGenSt Test Starts and runs the generator for 30 seconds fully testing t...

Страница 15: ...22 VDC 3 Activate the system by setting the AGS to AutoGenSt Enabl This is the normal operating setting When the coach s inside temperature reaches the START TEMP F or the START VOLTS DC setting the L...

Страница 16: ...VDC or 20 VDC to 24 VDC Quiet Time Range 9PM to 7AM 9PM to 8AM 9PM to 9AM 10PM to 8AM 11PM to 8AM Clock 24 hour Generator Run Range 1 to 5 hours 2 hours factory setting Connections Screw Terminals rea...

Страница 17: ...LUTION RED GEN FAULT Gen won t start Check Gen start wiring Turn off then enable to reset RED GEN FAULT Gen won t stay on Check Gen B wiring check gen turn off then enable to reset GREEN BLINK GEN STA...