©2010 Enerdrive Pty Ltd
5. Specifications
Weight (Controller)
0.5 kg
Weight (Switch)
0.1 kg
Dimensions (Controller)
7.6 cm H x 13.2 cm W x 3.3 cm D
Dimensions (Switch)
5.7 cm H x 8.3 cm W x 3.8 cm D
Electrical Requirements
12 VDC or 24 VDC
Controls
Enable, Off, Test
LED Indicator
On, Off, Fault Condition
Temp Sense Range
18 °C to 29 °C
25 °C - factory setting
Voltage Start Range
10 VDC to 12 VDC (or)
20 VDC to 24 VDC
Quiet Time Range
9PM to 7AM, 9PM to 8AM, 9PM to 9AM,
10PM to 8AM, 11PM to 8AM
Clock
24 hour
Generator Run Range
1 to 5 hours
2 hours - factory setting
Connections
Screw Terminals (rear mounted)
Electrical Connections
Gen B+ (from Gen Hour Meter) +12 VDC
+12 VDC or +24 VDC Pos (from Battery)
-12 VDC or -24 VDC Neg (from Battery)
Generator Start
Common (from Gen Start/Stop Switch)
Generator Stop/Preheat
AGS
AutoGenST Cntrl
Set Current Time
AutoGenSt OFF
Set Hour 12:00A
AutoGenSt Enabl
Set Minutes 12:00A
AutoGenSt Test
Set AM/PM 12:00A
AGS w/Queit Time
Table 2 - AGS Menu Tree
Содержание MagnaSine ME AGS
Страница 1: ...ME AGS Auto Gen Start Network System with Inverter and Remote for Coach Generators Operator s Manual...
Страница 2: ...2 2010 Enerdrive Pty Ltd...
Страница 10: ...10 2010 Enerdrive Pty Ltd 3 Installation Figure 3 AGS Wiring Diagram...
Страница 11: ...2010 Enerdrive Pty Ltd 11 3 Installation Figure 4 AGS Connector Pin Legend from left to right...
Страница 19: ...Templates Remote Control...