Enerdrive DOMETIC EN312100 Скачать руководство пользователя страница 36

Model

EN31220

EN31240

EN31260

EN32430

EN312100

Cooling

Forced air ventilation

Temperature Setting

Low, Normal, High (no sensor connected)

Battery Temperature 
Sensor Port

RJ12 (standard battery temperature sensor supplied)

Digital Display Port

RJ12 (optional display panel available)

Display:
LCD Display

Backlit display. Charging status, Battery Voltage and Output Current

Warning and Fault Code

Shown on display

AC Input and DC Output Connection:
AC Input Connection

IEC with Supplied 1.2M Power Lead

DC Output Connection

6mm Screws

8mm Studs

6mm Screws

DC Output Ground

Single Heavy Duty Common Ground Stud. 6mm ring terminals.

Environmental and Operating Temperature:
Storage Range

-40° to 70° C

Operating Range

-20° to 60° C

Humidity

5-95%, RH non-condensing

Ingress Protection

IP32 - Protected against solid objects over 2.5mm 

and water sprays up to 15º from vertical.

Base Unit Weight and Dimensions:
EN31220

2.4 Kg / 295 x 206 x 86 mm

EN31240

2.6 Kg / 295 x 206 x 86 mm

EN31260 / EN32430
EN312100

4.0 Kg / 356 x 206 x 99mm

6.4 Kg / 425 x 236 x 102.7mm

Optional Accessories:

Remote Digital Display / Enerdrive Part Number EN3REM

Regulatory Compliance:

Complies with AS/NZS 60335.2.29 Including Australian deviations.

Page 36

Enerdrive Battery Charger Owners Manual Rev. 5.4

Содержание DOMETIC EN312100

Страница 1: ...Owner s Manual Rev 5 4 2021 EN31220 Charger 12V 20Amp EN31240 Charger 12V 40Amp EN31260 Charger 12V 60Amp EN32430 Charger 24V 30Amp EN312100 Charger 12V 100Amp...

Страница 2: ...nerdrive Battery Charger Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Battery Char...

Страница 3: ...ial or incidental which might arise out of the use of such information The use of any such information will be entirely at the user s risk 3 Reminds you that if this manual is in any language other th...

Страница 4: ...Grounding Connection 19 DC OutputWiring 19 Recommended Cable Length Size And Required Fuse Size 19 StandardTemperature Sensor Connection 20 Optional Remote Display Connection 20 RunningThe Battery Cha...

Страница 5: ...rging 26 UnderstandingThe BatteryTemperature Functions 27 ProcedureTo Set OrView Charger Setting 28 GEL AGM Or Flooded BatteryType 28 Lithium BatteryType 29 Program Power Supply Type 30 ProcedureTo Eq...

Страница 6: ...ti bank battery charger to charge the different types of batteries you have installed in either your home boat caravan 4WD or commercial vehicle This manual will explain how to use this unit safely an...

Страница 7: ...in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Lead Acid Batteries produce explosive gases DO NOT smoke or have an o...

Страница 8: ...ual Rev 5 4 DO NOT use the Enerdrive Battery Charger in the vicinity of flammable fumes or gases such as gas bottles or large engines AVOID covering the ventilation openings Always operate unit in an...

Страница 9: ...h a separation diode and share a common charge algorithm During normal operation the Battery Charger will do a full charge cycle to float stage on battery bank one with battery types set to either GEL...

Страница 10: ...erature Sensor Port Remote Display Port Battery Positive Bank 3 Battery Positive Bank 2 Battery Positive Bank 1 Battery Negative Common DC Output fuses Unit Ground Enerdrive Battery Charger Owners Man...

Страница 11: ...t Display ACPower CableInput Battery Positive Bank 1 Battery Positive Bank 2 Battery Positive Bank 3 Battery Negative Common Unit Ground BTS Battery Temperature Sensor Port www enerdrive com au Page 1...

Страница 12: ...rged at full rated output current of the charger until the battery reaches its final charging voltage known as its absorption voltage In this step around 80 of the battery is recovered as fast as poss...

Страница 13: ...extended periods of time which will damage the battery bank The Battery Charger has two methods of load based regulation to ensure your battery charger transitions to float when it should do so www e...

Страница 14: ...pendent on chosen algorithm In the event of AC mains loss the charger will react according to time without mains power Loss of AC power for less than 4 min Charge resumes at existing stage Loss of AC...

Страница 15: ...www enerdrive com au Page 15 Lead Acid Profile...

Страница 16: ...y is based on twice the charger current rating EN31220 EN31240 EN31260 EN32430 Current Setting Battery Capacity Current Setting Battery Capacity Current Setting Battery Capacity Current Setting Batter...

Страница 17: ...ersonal injury or loss of life CAUTION Before Beginning Your Unit Installation Please Consider The Following The unit should be used or stored in an indoor area away from direct sunlight heat moisture...

Страница 18: ...the charger vertically provides the best thermal performance For installing in boat or marine environment the unit can be mounted horizontally and vertically AC and DC panel facing downwards only to...

Страница 19: ...rrent protection device usually within 20cm of each battery bank is required A DC disconnect switch is also recommended Both devices must be rated for DC voltage and current and be rated to withstand...

Страница 20: ...ative terminal of the charger Connect the other end of the negative wire to the negative terminal of the battery bank s or the load side of a battery monitor shunt if installed Place the DC Compartmen...

Страница 21: ...ubt simply connect a surge protector like you would use for your computer to the generator The Enerdrive Battery Charger will run very comfortably from many of the common market generators around the...

Страница 22: ...4 Battery Wiring Connecting The Batteries The Right Way For Single Bank Charging DO NOT Connect Bank 2 And 3 Outlet IMPORTANT NOTE EN31220 EN31240 EN31260 EN32430 Picture shows 12V setup 24V would con...

Страница 23: ...Positive Negative Battery Wiring Connecting The Batteries The Right Way For Single Bank Charging DO NOT Connect Bank 2 And 3 Outlet IMPORTANT NOTE EN312100 www enerdrive com au Page 23...

Страница 24: ...It will then switch to charge Bank 2 and 3 OR At start if the charger senses either Bank 2 or Bank 3 have voltage below 12V it will cycle to charge Bank 1 for 15 minutes then Bank 2 and 3 together fo...

Страница 25: ...nation current The charging process will terminate when the charging current drops to the set termination current Bulk re start occures when battery voltage drops below 13 3V DC 1 EN312100 can be prog...

Страница 26: ...ltage is held to constant voltage and the charging current will slowly reduce In Float stage the charger continuously produces lower constant float voltage to fully top up and maintain the battery in...

Страница 27: ...mperature sensor is used it is highly recommended to be installed on the main battery bank at the negative terminal Bank one The sensor senses the battery temperature and overrides the manual temperat...

Страница 28: ...related available Absorption to Float Mode current Model ChargingVoltage Maximum Charging Current Termination Charging Current EN31220 14 2V 14 3V 14 4V 20A 2A 4A 6A 15A 1 5A 3A 5A 10A 1A 2A 3A 5A 0 5...

Страница 29: ...he available termination charging current Model ChargingVoltage Maximum Charging Current Termination Charging Current EN31220 14 2V 14 3V 14 4V 20A 2A 4A 6A 15A 1 5A 3A 5A 10A 1A 2A 3A 5A 0 5A 1A 1 5A...

Страница 30: ...60A 40A 20A 5A EN32430 26 6V 27 0V 27 4V 30A 20A 10A 5A EN312100 13 3V 13 5V 13 7V 100A 80A 60A 40A Procedure To Equalise Flooded Battery DANGERExplosionhazardandriskofbatterydamage The battery gener...

Страница 31: ...When the battery equalisation is started the charger will automatically fully charge the selected channel first and follow with 1 hour of equalisation Check the battery electrolyte level during the e...

Страница 32: ...during the charging period function can switch to ON or OFF at any time during the charging period To set this function press and hold SEL key for 3 seconds to execute the Silent mode The unit is in s...

Страница 33: ...er current will de rate to 1 2 of the value A02 warning code will display The charger will recover automatically back to maximum charging current when the environmental temperature drops to below 45 C...

Страница 34: ...ion of the unit is blocked or the environmental temperature is high Reduce charging current or improve the ventilation near the unit E06 High battery temperature 70 C 60 C for Lithium is sensed by the...

Страница 35: ...diode isolation Selectable BatteryType Gel AGM Flooded Lithium Program Flooded default Standby Current 2 mA 5 mA 1 mA Charger Input AC InputVoltage Nominal 100 120 220 230 240VAC AC Input Operating R...

Страница 36: ...ews 8mm Studs 6mm Screws DC Output Ground Single Heavy Duty Common Ground Stud 6mm ring terminals Environmental and OperatingTemperature Storage Range 40 to 70 C Operating Range 20 to 60 C Humidity 5...

Страница 37: ...tions and claim process refer to the Enerdrive website https enerdrive com au warranty If you have purchased your product in Australia you should be aware that This warranty is provided in addition to...

Страница 38: ...Page 38 Enerdrive Battery Charger Owners Manual Rev 5 4...

Страница 39: ...www enerdrive com au Page 39...

Страница 40: ...Page 40 Enerdrive Battery Charger Owners Manual Rev 5 4...

Страница 41: ...www enerdrive com au Page 41...

Страница 42: ...Fill in the details below for your reference and convenience Serial Number Date of Purchase Purchased From Notes Page 42 Enerdrive Battery Charger Owners Manual Rev 5 4...

Страница 43: ...Notes www enerdrive com au Page 43...

Страница 44: ...Dometic Power Control Enerdrive Pty Ltd P O Box 9159 Wynnum Plaza Queensland Australia 4178 Ph 1300 851 535 Fax 07 3390 6911 Email support enerdrive com au Web www enerdrive com au...

Отзывы: