Program (Power Supply) Type
Parameters below are required for setting:
•
Supply Voltage 13.3, 13.5, 13.7 Vdc
•
Maximum available current (see table)
The following table shows the programmable voltage and the maximum current setting.
Model
Program Output Voltage Setting
Max. Current
EN31220
13.3V/13.5V/13.7V
20A/15A/10A/5A
EN31240
13.3V/13.5V/13.7V
40A/20A/10A/5A
EN31260
13.3V/13.5V/13.7V
60A/40A/20A/5A
EN32430
26.6V/27.0V/27.4V
30A/20A/10A/5A
EN312100
13.3V/13.5V/13.7V
100A/80A/60A/40A
Procedure To Equalise Flooded Battery
DANGER Explosion hazard and risk of battery damage
The battery generates explosive gases during equalisation. Follow all the battery safety precautions
listed in the manual. When using the equalisation mode, the user has to be sure the battery connected
to the channel is a flooded battery type. Equalising a non-flooded battery may overcharge the battery
and may cause the battery to explode.
Page 30
Enerdrive Battery Charger Owners Manual Rev. 5.4