operating Instructions and owner’s Manual

eNeRCo GRoUP, INC. |Indirect Fired Portable Heater

 warning

 Burner pressure shall not be adjusted: the 

heater is ready to run on the new gas 

Should it necessary to check the burner pressure: 
•  connect a manometer to the pressure port (14) , 
•  carry out the pressure reading on the manometer and turn 

the pressure regulator (15) if necessary to obtain the correct 
burner pressure value indicated in Tab. I 

Operating instructiOns 

switcHing On 

•  Make sure switch (8) is on “0”; 
•  Power the heater by means of the sectioning switch on the 

switchboard; 

•  If the unit is operated manually turn the switch (8) to 
•  The burner starts up, the combustion chamber heats up and 

then the fan starts; 

•   If the unit operates automatically set the room thermostat 

at the desired level and turn the control knob (8) to : the 
heater will now start and stop automatically. 

•   If after these operations, the generator does not work, refer 

to the “FAUlTS, CAUSeS AND ReMeDIeS” paragraph and 
find the cause. 

turning OFF 

•  In manual operation turn control knob (8) to “0” or turn off 

control in automatic operation. 

•  After switching off the machine, a post ventilation time is 

electronically set by a control flame box to lower the com-
bustion chamber temperature (usually post ventilation lasts 
for 90 sec). 

 warning 

Finally, close the gas supply stopcock and 

turn of the sectioning switch (Fig. 1). 

VentilatiOn 

To obtain the ventilation effect only, simply turn the switch (8) to 
the position marked by the symbol  to start the machine. To stop 
it, turn the switch to “o”/oFF (Fig. 1). 

transpOrt and Handling 

The heater can be raised and hung up using the four anchor holes 
on the casing. 

 warning 

Before moving the unit: 

•  Stop the machine as indicated in the “STOP” paragraph; 
•  Disengage the power supply by removing the plug from the 

power socket; 

•  Fully unscrew the fitting connecting the gas hose pipe to 

the heater; 

•  Wait for the heater to cool down. 

Maintenance 

To regulate operation of the unit, the fans, combustion chamber, 
the burner must be periodically cleaned. 

 warning 

Before performing any maintenance 

operation: 

•  Stop the machine as indicated in the “STOP” paragraph; 
•  Disengage the power supply by removing the plug from the 

power socket; 

•  Close the gas supply stopcock; 
•  Wait for the heater to cool down. 

During cleaning any foreign bodies must be removed from the fan 
suction grille. 

 warning 

Do not direct jets of compressed air 

towards the air pressure points near the main fan: the air 
pressure switch could be permanently damaged. 

Содержание HeatStar 400IDG

Страница 1: ...251 0001 NATURAL GAS LPG FIRED HEATER heatstar BY eNERCO If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of li...

Страница 2: ...DERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR H...

Страница 3: ...page 5 and connected to an electrical switchboard When the heater is connected to a flue pipe the flue pipe shall terminate in a vertical section at least 3 feet long and sufficient draft shall be cre...

Страница 4: ...ut Plug in the power cord having read the rating plate that specify electric supply characteristics Connect accessories such as the room thermostat or clock to the unit s control panel with the thermo...

Страница 5: ...ime is electronically set by a control flame box to lower the com bustion chamber temperature usually post ventilation lasts for 90 sec Warning Finally close the gas supply stopcock and turn of the se...

Страница 6: ...s on The ionisation electrode does not detect a flame Remove the flame sensor and clean it Safety thermostat tripped due to the combus tion chamber overheating Check that the suction and the flow gril...

Страница 7: ...type AWG 16 or AWG 18 wire or its equivalent as by here specified AP CONTROL BOX TA ROOM THERMOSTAT PLUG ST ELECTRIC PILOT LAMP FU FUSE LI1 OVERHEAT THERMOSTAT EV1 SOLENOID VALVE I Stage MB BURNER MO...

Страница 8: ...8 ENERCO GROUP INC Indirect Fired Portable Heater Operating Instructions and Owner s Manual 4000IDG Series Indirect Fired Heater...

Страница 9: ...508 Fuse holder 47 E10324 Fuse 6x30 25A 49 E20319 Terminal board 50 E20305 Terminal board 51 E10931 Transformer H T BRHAMA 52 E40229 Control box BRAHMA TGRD 81 120V 53 G06073 Plate for electrical comp...

Страница 10: ...sportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Technical Support Department at 800 25...

Отзывы: