Operating instructiOns and Owner’s Manual

read instructiOns careFullY:

 Read and follow all instructions. 

Place instructions in a safe place for future reference. Do not allow 
anyone who has not read these instructions to assemble, light, adjust or 
operate the heater.

Mo
D

el

4000IDG

01/10 #?????

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001

natural gas/lpg Fired Heater

Heatstar

BY enercO

if the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or loss of life.

warning:

 —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 

other appliance.

—  Service must be performed by a qualified service agency.

This is a vented portable heater. It uses air (oxygen) from the area in which it is used. Adequate 
combustion air and ventilation must be provided. Refer to page 5.

Содержание HeatStar 400IDG

Страница 1: ...251 0001 NATURAL GAS LPG FIRED HEATER heatstar BY eNERCO If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of li...

Страница 2: ...DERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR H...

Страница 3: ...page 5 and connected to an electrical switchboard When the heater is connected to a flue pipe the flue pipe shall terminate in a vertical section at least 3 feet long and sufficient draft shall be cre...

Страница 4: ...ut Plug in the power cord having read the rating plate that specify electric supply characteristics Connect accessories such as the room thermostat or clock to the unit s control panel with the thermo...

Страница 5: ...ime is electronically set by a control flame box to lower the com bustion chamber temperature usually post ventilation lasts for 90 sec Warning Finally close the gas supply stopcock and turn of the se...

Страница 6: ...s on The ionisation electrode does not detect a flame Remove the flame sensor and clean it Safety thermostat tripped due to the combus tion chamber overheating Check that the suction and the flow gril...

Страница 7: ...type AWG 16 or AWG 18 wire or its equivalent as by here specified AP CONTROL BOX TA ROOM THERMOSTAT PLUG ST ELECTRIC PILOT LAMP FU FUSE LI1 OVERHEAT THERMOSTAT EV1 SOLENOID VALVE I Stage MB BURNER MO...

Страница 8: ...8 ENERCO GROUP INC Indirect Fired Portable Heater Operating Instructions and Owner s Manual 4000IDG Series Indirect Fired Heater...

Страница 9: ...508 Fuse holder 47 E10324 Fuse 6x30 25A 49 E20319 Terminal board 50 E20305 Terminal board 51 E10931 Transformer H T BRHAMA 52 E40229 Control box BRAHMA TGRD 81 120V 53 G06073 Plate for electrical comp...

Страница 10: ...sportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Technical Support Department at 800 25...