background image

MMD (ID)

Option Switch

Master MMX [0]

Slave MMX [] ~ 
Slave MMX []

•  When installing a master MMX and three slave MMXs with the NTSC video signal.

MMD (ID)

Option Switch

Slave MMX [3]

MMD (ID)

Option Switch

Master MMX [0]

Slave MMX [] ~ 
Slave MMX [4]

•  When installing a master MMX, 6 slave MMXs and four spot MMXs with the NTSC video signal.

MMD (ID)

Option Switch

Slave MMX [5]

Spot MMX [0] ~ 
Spot MMX [3]

NOTES:
•  The option switch setting determines the operation mode of MMXs: Master MMX, slave MMX, spot MMX.  
  − A master MMX is a basic MMX in the MMX system and has information of slave MMXs daisy-chained to  
    the master MMX. A main monitor is connected to the master MMX and provides various functions.  
  − A slave MMX is subjective to a master MMX and daisy-chained to the master MMX for proper function.   
    It does not have its own settings except the IP address setting, and the settings of a master MMX are  
    applied to slave MMXs automatically. 
  − A spot MMX is connected to a master MMX and slave MMXs and displays video from spot outputs of a  
    master MMX and slave MMXs on up to four spot MMX monitors at the same time.
•  It is required to perform factory reset in all daisy-chained MMXs and set up the system all over again to  
  complete the settings. The MMX system might not work properly when applying previously saved settings  
  to the MMXs after the factory reset. Refer to 

Factory Reset  

(see next page) for details on the factory reset.

Software Upgrade

You can upgrade the software remotely while the MMX is turned on by running the INIT program. The MMX restarts 
after completing the upgrade. Refer to the INIT User’s Manual for details.

NOTE:  All of the master MMX, slave MMXs daisy-chained to the master and spot MMXs connected to the  
 

master MMX and slave MMXs should be upgraded with the same upgrade file. Otherwise, the MMX  

 

system might not work properly.

Содержание MMX

Страница 1: ...Instruction Manual MMX Network Controlled Video Matrix System...

Страница 2: ...em with DVRs 25 5 Monitor Layout and Control 33 5 1 Main Monitor 33 5 2 Quad Monitor 39 5 3 Spot Monitor 42 5 4 Spot MMX Monitor 44 6 Configuration 47 6 1 System 48 6 2 Network 51 6 3 Video 55 6 4 Eve...

Страница 3: ...excessive heat dust damp and vibration Do not place any heavy objects on the unit To disconnect the power cord of the unit pull it out by the plug Never pull the cord itself Pay attention when laying...

Страница 4: ...figure one Master since it keeps all information and controls the Slaves Customized layout The combination of multiple MMX devices will create a matrix system of 16 to 256 cameras Each of these camera...

Страница 5: ...pical Applications Medium Sized System without DVRs NOTE The MMX is controlled by a network keyboard via Ethernet Refer to the user s manual of network keyboard on instructions for using the network k...

Страница 6: ...e medium sized system without DVRs Medium Sized System with DVRs You can monitor video from cameras connected to the MMX through Loop Out ports of DVRs You can control DVRs if Main Outs of the DVRs ar...

Страница 7: ...splayed on the spot MMX monitors connected to the spot MMXs in the single screen layout and you can change the monitoring channel by using a network keyboard at any time Video from cameras of a DVR co...

Страница 8: ...tors The voltage range of the alarm input is from 0V to 5V The threshold voltage of electrical switches for NC Normally Close is above 2 4V and for NO Normally Open is below 0 3V and should be stable...

Страница 9: ...s booting when power is applied NOTES Do NOT connect a cable to the Loop BNC unless it is connected to another device because it will cause poor quality video To make connections on the Alarm Connecto...

Страница 10: ...chain all slave MMXs to a master MMX by using the STP Cat5E cable with an RJ 45 jack when using more than one MMX Connect a cable from the DAISY CHAIN OUT port of a MMX with a higher ID number to the...

Страница 11: ...format is PAL 2 END OF SLAVES The MMX is a slave MMX with the highest ID number among all slave MMXs The MMX is a spot MMX The MMX is the only one MMX Other cases except when the switch is set to the...

Страница 12: ...t the IP address setting and the settings of a master MMX are applied to slave MMXs automatically A spot MMX is connected to a master MMX and slave MMXs and displays video from spot outputs of a maste...

Страница 13: ...a buzzer sounds The MMX resets to factory defaults and restarts after completing the factory reset You can perform a factory reset remotely while the MMX is turned on by running the INIT program and s...

Страница 14: ...System without DVRs When connecting cameras directly to the MMXs you can monitor video of user defined channels on monitors con nected to the MMXs 1 Connect cameras to the Video In ports of a master...

Страница 15: ...n Switch Slave MMX Set up the unique MMX ID for each slave MMX from 1 to 63 in order and set the END OF SLAVES switch to the On or Off position depending on the slave MMXs ID setting Set the END OF SL...

Страница 16: ...toring are supported in each monitor 5 Connect MMXs to network via Ethernet connections through the NETWORK port on the rear panel All MMXs should be networked via Ethernet 6 Run the INIT program and...

Страница 17: ...or layout 7 Run the INIT program and connect to a network keyboard Refer to the User s Manual of the network keyboard for details on setting up the network keyboard 7 1 Go to the following menus Remot...

Страница 18: ...ould have its own unique ID Type Set up the camera type Fixed Select if the camera is not a PTZ camera PTZ Camera Select if the camera is a PTZ camera You can control the PTZ camera by using a network...

Страница 19: ...s to control to the Video In ports of a master MMX or a slave MMX The number of cameras that can be connected to the DVRs decreases as the number of DVRs connected to the master MMX and slave MMXs You...

Страница 20: ...n Switch Slave MMX Set up the unique MMX ID for each slave MMX from 1 to 63 in order and set the END OF SLAVES switch to the On or Off position depending on the slave MMXs ID setting Set the END OF SL...

Страница 21: ...e master MMX or slave MMXs 7 Connect MMXs to network via Ethernet connections through the NETWORK port on the rear panel All MMXs should be networked via Ethernet 6 Connect quad monitors or spot monit...

Страница 22: ...n the list Master MMX ID 0 slave MMX ID 1 to 63 8 2 Go to the following menus Remote Setup Video Main Monitor Quad Monitor Spot Monitor Select a monitor and click the Edit button to set up layouts Ref...

Страница 23: ...9 4 Click the Digital Video Recorder pull down menu in the device list then the registered DVR s pull down menu A list of monitors and cameras supported in the DVR is displayed ID Main Monitor Display...

Страница 24: ...ix pull down menu in the device list then the registered MMX s pull down menu A list of monitors and cameras supported in the MMXs is displayed ID Main Monitor Displays the monitor ID and type ID Spot...

Страница 25: ...e PTZ camera by using a network keyboard 4 3 Enterprise Sized System with DVRs When connecting DVRs to the MMXs you can monitor video of user defined channels on monitors connected to the MMXs You can...

Страница 26: ...spot MMXs The number of spot outs of each master MMX and slave MMX connected to the spot MMXs should be the same The cable connection between the master MMX or slave MMXs and spot MMXs is different d...

Страница 27: ...for each spot MMX from 0 to 3 and set the END OF SLAVES switch of each spot MMX to the On position and the SPOT MODE switch to the On position ID MMX ID Switch 0 Option Switch Slave MMX Set up the uni...

Страница 28: ...u can monitor video from any cameras in various layouts and sequence and event monitoring are supported You can also control DVRs connected to the master MMX or slave MMXs 7 Connect quad monitors to t...

Страница 29: ...ork via Ethernet connections through the NETWORK port on the rear panel All MMXs should be networked via Ethernet 10 Run the INIT program and connect to the master MMX Refer to the INIT User s Manual...

Страница 30: ...he spot MMX if the spot MMX is not displayed in the list 12 1 Go to the following menus Remote Setup Device General Select Advanced from the Device type drop down menu 11 1 Go to the following menus R...

Страница 31: ...4 Click the Digital Video Recorder pull down menu in the device list then the registered DVR s pull down menu A list of monitors and cameras supported in the DVR is displayed ID Main Monitor Displays...

Страница 32: ...ress Control Port User ID Password Enter the IP address port number user ID and password for the connection to the MMX 12 8 Click the Matrix pull down menu in the device list then the registered MMX s...

Страница 33: ...can also monitor video from any camera channels and control the DVRs or PTZ cameras on the monitor by using a network keyboard The MMX should be registered on the network keyboard properly to control...

Страница 34: ...menus Remote Setup Video Main Monitor Saved layouts are displayed in the list Click the Add button to add a new layout max 29 and the Edit button to edit the saved layout Selecting a layout and click...

Страница 35: ...ence list in the right Adjust the sequence order by using the and button and set up the sequencing interval Enter the group name and click the OK button Clicking the Sequence Monitoring in the Sequenc...

Страница 36: ...deo from selected channels is displayed in the main monitor in the user defined layout Controlling Main Monitor Display You can change the layout of the main monitor by using a network keyboard You ca...

Страница 37: ...The layout changes Controlling Cameras on Main Monitor You can monitor video from a channel and control a camera in the desired pane of the main monitor by using a network keyboard 1 Press the main mo...

Страница 38: ...etwork keyboard Remote Setup Device Setup Digital Video Recorder ID DVR name 6 Press the button The DVR s main monitor screen is displayed in the selected pane and you can control the DVR by using dev...

Страница 39: ...etting up event monitoring Sequence monitoring and event monitoring are not supported in a quad monitor at the same time Quad Monitor Layout 1 Run the INIT program and connect to the master MMX Refer...

Страница 40: ...a max 126 for sequence monitoring and click the button The selected camera is added to the sequence list in the right Adjust the sequence order by using the and button and set up the sequence duration...

Страница 41: ...nd click the OK button Clicking the Event Monitoring in the Sequence Event Group List in the left displays the registered event monitoring group in the list Select the group and allocate the selected...

Страница 42: ...ayout for details of setting up sequence monitoring Event monitoring allows you to monitor event detected video when the user defined events occur at the user defined camera channels Camera channels a...

Страница 43: ...ideo from the camera is displayed in the spot monitor and you can control the camera by using PTZ control buttons if the camera is a PTZcamera 1 Press the spot monitor s ID by using the network keyboa...

Страница 44: ...ntrol the camera by using PTZ control buttons if the camera is a PTZ camera 5 4 Spot MMX Monitor A spot MMX monitor is connected to a spot MMX You can monitor video from a master MMX or slave MMXs con...

Страница 45: ...eck the spot MMX monitor s ID by running the INIT program and connecting the network keyboard Remote Setup Device Setup Matrix ID Spot MMX Monitor 2 Press the button 3 Press the camera ID You can chec...

Страница 46: ...board Remote Setup Device Setup Digital Video Recorder ID DVR name 4 Press the button The DVR s main monitor screen is displayed in the spot MMX monitor and you can control the DVR by using device con...

Страница 47: ...rs Refer to the following master MMX s settings for details on setting up a spot MMX NOTE The Remote Setup is not supported for slave MMXs A slave MMX does not have its own settings except the IP addr...

Страница 48: ...t Click to return all except network related settings to the original factory settings Import Click to apply the settings saved as a mda file format to a master MMX and all slave MMXs daisy chained to...

Страница 49: ...zone and turn daylight saving time on or off by checking the box Clicking the Apply button applies the changes immediately Time Sync Automatic Sync Check the box to automatically synchronize the time...

Страница 50: ...r Edit Select a group and click the button to change authority levels assigned to the group or select a user and click the button to change the user s password Remove Select a group or user and click...

Страница 51: ...ou can change the network settings and set up DVRNS function IP Address Master MMX and Slave MMXs You can set up the network connection information of the master MMX and all slave MMXs daisy chained t...

Страница 52: ...Ask your Internet service provider for information about the IP Address of the DNS Server Spot MMXs When a spot MMX is connected to the master MMX and slave MMXs you have to connect to a spot MMX and...

Страница 53: ...ad of its IP address For the DVRNS function to work properly the MMX should be registered on the DVRNS server and the DVRNS server settings in the MMX system should match the settings registered on th...

Страница 54: ...toring function Control Set up the port number for the remote control by a network keyboard When changing the port settings you must change the port settings on a network keyboard also NOTES The MMX r...

Страница 55: ...displays video and OSD information on the screen Selecting Covert 1 displays only OSD on the screen but no video Selecting Covert 2 neither video nor OSD information displays and the camera input appe...

Страница 56: ...Refer to Main Monitor Setup Layout below for details Set Default Select a layout to apply in the main monitor and click the button The selected layout is set as a default layout and video is displaye...

Страница 57: ...ick the Add button Sequence Monitoring Enter a group name select cameras to register in the group from the camera list in the left and click the button The selected camera will be added to the list in...

Страница 58: ...ad monitor in the list and click the button A layout setup screen appears and a camera list of the MMX that the quad monitor is connected is displayed in the left of the setup screen Refer to Main Mon...

Страница 59: ...ot monitor in the list and click the button A layout setup screen appears and a camera list of the MMX that the spot monitor is connected is displayed in the left of the setup screen Refer to Main Mon...

Страница 60: ...Master Slave MMX Spot MMX Connection Displays the cable connection between a master MMX or slave MMXs spot output and spot MMXs video input Clicking the icon displays the connection information on a...

Страница 61: ...Title Check the box to display the camera name Event Check the box to display the event status PTZ Check the box to display the icon when the camera is set to a PTZ camera The icon flickers during th...

Страница 62: ...arm Out Select to trigger an alarm output signal Email Callback Select to send an Email Callback Select to send a message to remote sites and select the desired remote sites PTZ Preset Click the desir...

Страница 63: ...to remote sites and select the desired remote sites PTZ Preset Click the desired PTZ camera and select the desired preset number to move a PTZ camera to the previously saved preset location You must...

Страница 64: ...n Setup screen appears Check the box for each action the MMX will take whenever it detects a video loss event Alarm Out Select to trigger an alarm output signal Send Email Select to send an Email Remo...

Страница 65: ...the SMTP server Select Use SSL TLS if the SMTP server requires SSL Secure Sockets Layer authentication Authentication ID Password Enter the ID and password if the SMTP server requires user authenticat...

Страница 66: ...ween DVRs and MMXs Check that video is displayed on the monitor connected to a DVR If video is not displayed check the DVR settings and camera connection to the DVR referring to the DVR User s Manual...

Страница 67: ...nt Full picture and sequential monitoring Alarm inputs 16 Alarm output 2 Alarm reset input yes Alarm processing Motion detection Alarm in Video loss Alarm Out email callback PTZ preset Cascading Maste...

Страница 68: ...k and Jog Shuttle 5VDC Type MMX Art No 90556 Power consumption 30watts Temperature range Operation 0 40 C Housing Steel metal Colour Black Dimensions HxWxD 88 x 430 x 405mm Weight 4 3kg Parts supplied...

Страница 69: ...Pin Outs I O Connector AI 1 to 16 Alarm Inputs GND GND Chassis Ground NC Alarm Out Normally Closed C Common NO Alarm Out Normally Open ARI Alarm Reset In RS 485 Connector Master Unit Slave Unit RX TX...

Страница 70: ...010 17 100010 18 010010 19 110010 20 001010 21 101010 22 011010 23 111010 24 000110 25 100110 26 010110 27 110110 28 001110 29 101110 30 011110 31 111110 32 000001 33 100001 34 010001 35 110001 36 001...

Страница 71: ...es given by the MMX system Otherwise the MMX system might not work properly Check the cable connec tion information by running the INIT program and setting up the spot MMX monitors in Remote Setup Ref...

Страница 72: ...nnection One Connection of Two Spot MMX Monitors The number of spot MMXs necessary for the connection One Master MMX and Slave MMXs Spot MMX Master MMX 0 Spot Out 1 to Spot MMX 1 0 Video In 1 Master M...

Страница 73: ...Slave MMX 2 Spot Out 2 to Spot MMX 1 0 Video In 11 Slave MMX 3 Spot Out 1 to Spot MMX 1 0 Video In 4 Slave MMX 3 Spot Out 2 to Spot MMX 1 0 Video In 12 Slave MMX 4 Spot Out 1 to Spot MMX 1 0 Video In...

Страница 74: ...eo In 12 Slave MMX 3 Spot Out 3 to Spot MMX 2 0 Video In 4 Slave MMX 3 Spot Out 4 to Spot MMX 2 0 Video In 12 Slave MMX 4 Spot Out 1 to Spot MMX 1 0 Video In 5 Slave MMX 4 Spot Out 2 to Spot MMX 1 0 V...

Страница 75: ...Out 2 to Spot MMX 2 1 Video In 4 Slave MMX 3 Spot Out 3 to Spot MMX 3 2 Video In 4 Slave MMX 3 Spot Out 4 to Spot MMX 4 3 Video In 4 Slave MMX 4 Spot Out 1 to Spot MMX 1 0 Video In 5 Slave MMX 4 Spot...

Страница 76: ...deo In 12 Slave MMX 11 Spot Out 3 to Spot MMX 3 2 Video In 12 Slave MMX 11 Spot Out 4 to Spot MMX 4 3 Video In 12 Slave MMX 12 Spot Out 1 to Spot MMX 1 0 Video In 13 Slave MMX 12 Spot Out 2 to Spot MM...

Страница 77: ...77 Appendix 4 Map of Screens Remote Setup...

Страница 78: ...78...

Страница 79: ...79...

Страница 80: ...xclusive distribution through specialised trade channels only VIDEOR E Hartig GmbH Carl Zeiss Stra e 8 63322 R dermark Germany Tel 49 0 6074 888 0 Fax 49 0 6074 888 100 www videor com V 1 0 Technical...