MOTOR SETUP
Motor Setup menu provides the pan and tilt speed of a camera. User can set the desired
speed with pushing the
Joystick
to the left or right. During operation, pressing
153
+ ON
keys
will change the speed to the SLOW mode and pressing
153
+ OFF
keys will change the
speed to the NORMAL mode.
Press and hold the
CTRL
key and moving the
Joystick
will operate with the TURBO speed
mode.
MOTOR SETUP
PROPORTIONAL P/T : ON
P/T MODE : NORMAL
SLOW PAN MAX : 40
SLOW TILT MAX : 40
NORMAL PAN MAX : 90
NORMAL TILT MAX : 90
TURBO PAN MAX : 360
TURBO TILT MAX : 100
SAVE AND EXIT(ESC TO CANCEL)
PROPOTIONAL P/T
ON, OFF
P/T MODE
SLOW, NORMAL, TURBO
SLOW PAN Maximum speed
19
°
~ 90
°
/second
SLOW TILT Maximum speed
19
°
~ 90
°
/second
NORMAL PAN Maximum speed
40
°
~ 360
°
/second
NORMAL TILT Maximum speed
40
°
~ 200
°
/second
TURBO PAN Maximum speed
200
°
~ 380
°
/second
TURBO TILT Maximum speed
90
°
~ 300
°
/second
PASSWORD EDIT
PASSWORD EDIT SETUP
(CTRL KEY)
INPUT PASSWORD
PASSWORD:
A B C D E F G H I J
K L M N O P Q R S T
U V W X Y Z 0 1 2 3
4 5 6 7 8 9 ( )
SAVE AND EXIT(ESC TO CANCEL)
You can change the password with 6-digit character in this menu.
The default password is
555555
.
When the password enable is on, the input password window displays to enter the menu.
At this time, move the cursor to the desired character with the
Joystick
and press the
CTRL
or
IRIS Open
key.
27
Содержание HDD-2030PTZ1080
Страница 1: ...EN User Manual 1 2 8 HDcctv Dome PTZ 30x Day Night 4 3 129mm 1920x1080 Indoor HDD 2030PTZ1080...
Страница 11: ...Figure 8 Termination Diagram 6...
Страница 36: ...Figure Dimension 31...