Endura 40100A04 Скачать руководство пользователя страница 3

- 3 -

Glossary of Terms

Table of Contents

HGI:

  

Industry abbreviation for Hydromechanical 

Grease Interceptor.

 By definition an HGI is designed to use 

managed flow, air entrainment and specifically designed 
features to provide an enhanced level of separation 
efficiency, removing non petroleum FOG (Fats, Oil and 
Grease) from a transition flow of waste water, generated by 
commercial foodservice activities (Restaurants, Cafeterias, 
Institutional Kitchens , Sandwich Shops and Coffee houses 
for example). HGI’s are performance tested for efficiency of 
grease separation based on National Standards. 

Operational Cost Index =1

GGI:

  

Industry abbreviation for Gravity Grease 

Interceptor. 

 By definition a GGI has a minimum of 350USG 

capacity and in operation 500USG to 1500USG of capacity 
are most common. No flow control device. Separation 
of FOG based on capacity and retention time of water 
(minimum 30 min. to exchange volume). At this time no 
performance Standards are published for GGI’s. 

Operational Cost Index   HGI = 5     GGI = 10+

GRD:

  

Industry abbreviation for Grease Removal 

Device. 

 Designed  firstly as an HGI, a GRD uses a heat source 

and a timed or sensor based skimming (or draw-off ) device 
to remove accumulated FOG from the separation chamber 
into an external container for collection and disposal. These 
units require daily maintenance for management of food 
solids.  

Operational Cost Index   HGI = 2.5     GGI = 5

AHJ:

  

Authority Having Jurisdiction. 

 This can be

one or more government departments - for example plan 
check/review, building, plumbing, pretreatment, sewer and 
waste water. Bottom line...those who enforce the rules and 
regulations.

Cost Index:

  

A way of indicating the relative cost

of different types of interceptor to each other for broad 
comparison purposes. This includes product purchase, 
installation cost and typical maintenance.

25% Rule:

  

The rule of thumb, sometimes mandated

by jurisdiction, used to determine frequency of pump 
out for GRAVITY GREASE INTERCEPTORS. The 25% refers 
to the combined volume or retained FOG and food solids 
which shall not exceed 25% of the working volume of the 
interceptor. This rule should not typically be applied to HGI’s 
particularly those with extended capacity.

Air Entrainment:

  

Mixing of air with Influent using

a flow control device. Air and grease are attracted to each 
other, the air wanting to separate more easily than grease. 
Because they become mixed together the air increases the 
efficiency of separation.

Effluent:

  

Waste water containing little to no FOG,

being discharged out of the interceptor.

Influent:

  

Waste water containing uncontrolled

and variable levels of FOG based on the nature and 
practices of the foodservice operation.

Separation Chamber:

  

Zone inside the

interceptor where grease separates from water and is 
retained.

– Available online

– Mobile Friendly

– Best Management Practices

BMP

Page

Features Overview 

2

Glossary 

3

Quick Start Installation Guide 

4

Technical Information 

6

Installation Specifications 

8

Installation 

11

Installation - Flow Controls 

12

Remote Pump (optional) 

13

Page

Installer Checklist 

14

Operation 

15

Maintenance 

16

Pumper Checklist 

18

Trouble Shooting 

19

Frequently Asked Questions 

20

Warranty 

23

Registration Card 

24

Содержание 40100A04

Страница 1: ...appurtenance your Endura grease interceptor MUST be isolated from the drainage system in the event that nal drain testing or other system pressure testing is required DO NOT under any circumstances s...

Страница 2: ...latest addition to the proven line of Endura Grease Management products We have spent many thousands of hours in the development of Endura XL our aim being simple to produce the industry s best Hydrom...

Страница 3: ...heck review building plumbing pretreatment sewer and waste water Bottom line those who enforce the rules and regulations Cost Index A way of indicating the relative cost of different types of intercep...

Страница 4: ...mum safety factor of 2 shall be applied in calculation design Concrete Anchor Base if anchoring is required Min 6 Inle O t utlet Min 12 Min 12 Min 8 6 Minimum Base of Crushed aggregate material approx...

Страница 5: ...Extension Installation Guide 8 Finish to grade floor For in ground applications with vehicular traffic the upper 8 requires a reinforced concrete slab Refer to the Installation Specification section o...

Страница 6: ...150 gpm tank 4 Spigot connections with S Rated Lids 1 40150A04 Endura XL 150 gpm tank 4 Spigot connections with M Rated Lids 1 40150A04M Endura XL 150 gpm tank 4 Threaded connections with S Rated Lid...

Страница 7: ...hall additionally operate with an air balanced environment to equalize variation in internal pressures being controlled and maintained with an appropriately sized air balance means be supported by a L...

Страница 8: ...ongitudinally 1 6 anchoring may however be necessary as determined by the specifying engineer Tie down locations are incorporated to the tank and can be used in conjunction with coated stainless steel...

Страница 9: ...y specifying engineer 2 BACKFILLING FINISHED CONCRETE SLAB TRAFFIC LOAD RATED AASHTO 304 H20 16 000lbs and approved to CSA B481 0 Class S 20 F to 100 F 29 C to 38 C 2 1 Preparation of sub grade per lo...

Страница 10: ...ol If Required External Flow Control If Required GR N I E S A E R E T C P E T R O GR N I E S A E E T RC P E T R O GREA N I E S R E T C P E T R O GR N I E S A E R E T C P E T R O Endura XL grease inter...

Страница 11: ...criterial are met See Page 12 Trapping equivalent in compliance with applicable plumbing code requirements Venting The installation of the interceptor shall be vented downstream in accordance with lo...

Страница 12: ...main drain line connected to the interceptor The remain accessible for maintenance and The location of the cleanout should be recorded in you Installer Hand Over Check List See Page 14 is important th...

Страница 13: ...enetration tank seal Part 40100 TPS into the opening prepared and lubricate well using silicone pipe lubricant 6 As the orientation of the pipe when installed is important mark or identify on the top...

Страница 14: ..._______ Connections Cleanouts Mark where installed Extension Risers added Yes if Yes approx length of riser installed _________in m No Flow Control Handle Extended Yes No See Riser Extension Instructi...

Страница 15: ...place and well tightened MissingboltsMUSTbereportedtomanagementandreplacedimmediately Covers MUST meet the required load rating for the application see the Technical Information section Do NOT use alt...

Страница 16: ...ght sampling air balance cap must be raised also Air Balance Hole Maintenance IMPORTANT Regular Removal of Fat Oil and Grease Due to the capacity of your Endura XL Grease Interceptor it is necessary t...

Страница 17: ...of damage to the internal flow control where fitted by rooting or other equipment Access to the Outlet Well Although essentially a closed area the outlet system is able to be accessed by removal of th...

Страница 18: ...olume of Waste Removed _____________________ Gallons Liters Inlet Baffle Opened Inspected Yes No Flow Control Checked Cleaned Yes No Note The flow control device internal or external shall be inspecte...

Страница 19: ...equency I think I have missing parts Parts have been removed or lost during prior servicing Check exploded drawing in this manual to confirm the parts that are supposed to make up your interceptor mod...

Страница 20: ...Load Drainage Period 70 84 1 min 70 84 l p m 70 84 2 min 35 42 l p m 5 Select Interceptor falls between two sizes select the larger of the two interceptors For a one minute drainage period For a two m...

Страница 21: ...ivalent is not directly achievable by application of a standard formula As an experienced manufacturer in the Grease Management market we have been able to identify and validate a a manufacturers reco...

Страница 22: ...nce will be proportionally less too Rates will vary significantly by region and by contractor Always use a licensed or approved contractor to maintain your interceptor Do Endura XL tanks need to be di...

Страница 23: ...th the Products or on Manufacturer s website ii the Products have been installed and used in strict compliance with Manufacturer s written instructions as published and updated from time to time by Ma...

Страница 24: ...Email us feedback endurainterceptor com Limited LifetimeWarranty Registration Card Congratulations on your purchase of the Endura XL Grease Interceptor This product is supplied with a the manufacturer...

Отзывы: