Tophit H CPS471/CPS471D

16

Hauser

Certificates and approvals

Ex approval FM/CSA

• FM

Cl. I, Div. 1, Groups A, B, C, D, associated apparatus Mycom S 153-O/-P or Liquiline M CM42-NP/-PP

• CSA

Cl. I, Div. 1, Groups A, B, C, D, associated apparatus Mycom S 153-S or Liquiline M CM42-NS/-PS

Ex approval ATEX

Device group II, Category 1G
Explosion protection EEx ia IIC T3/T4/T6

Sanitary compatibility EHEDG

Sterilisability validated acc. to EHEDG test criteria (TNO Report V3640 RE)

Original of report summary

"At the request of Hauser Conducta, Postfach 100154, D-70826 Gerlingen, Germany the in-place 
cleanability of the ISFET-Sensor TopHit CPS 471 was assessed according to the test procedure of the 
European Hygienic Engineering & Design Group (EHEDG).
The test results show that the ISFET-Sensor TopHit CPS 471, including the seals, is cleanable in-place at least 
as well as the reference pipe. The tests were conducted five times on one test object. The results of the tests 
are comparable with each other. The ISFET-Sensor TopHit CPS 471 complies with the hygienic criteria of the 
Machinery Directive 98/37/EC, annex 1 (additional essential health and safety requirements for certain 
categories of machinery) section 2.1 (agri-foodstuffs machinery), the hygienic requirements of EN 1672 - part 
2 and with the hygienic equipment design criteria of the EHEDG.
The test results obtained are representative of the ISFET-Sensor TopHit type CPS 471 and type CPS 441."

• Materials in contact with medium are FDA certified
• Certified acc. to the 3-A standard no. 74-02

Accessories

Transmitters

• Liquiline M CM42

Modular two-wire transmitter, stainless steel or plastic, field or panel instrument, 
various Ex approvals (ATEX, FM, CSA, Nepsi, TIIS),
HART, PROFIBUS or FOUNDATION Fieldbus available
Ordering acc. to product structure, see Technical Information (TI381C/07/en)

• Liquisys M CPM223/253

Transmitter for pH and redox, field or panel-mounted housing,
HART or PROFIBUS available
Ordering acc. to product structure, see Technical Information (TI194C/07/en)

• Mycom  S  CPM153

Transmitter for pH and redox, one or two channel version, Ex or Non-Ex, 
HART or PROFIBUS available
Ordering acc. to product structure, see Technical Information (TI233C/07/en)

Fully automatic measuring 
systems

Topcal S CPC310
• Fully automatic measuring, cleaning and calibration system; Ex or Non-Ex
• in-situ cleaning and calibration, automatic sensor monitoring
• Ordering acc. to product structure, Technical Information TI404C/07/de

Topclean S CPC30
• Fully automatic measuring and cleaning system; Ex or Non-Ex
• in-situ cleaning, automatic sensor monitoring
• Ordering acc. to product structure, see Technical Information TI235C/07/en

Service tool

Memocheck Plus CYP01D, Memocheck CYP02D
• Tool for the qualification of measuring chains
• Service tool for quick, on-site checks of measuring systems with Memosens technology
• Verification of data transmission
• Ordering acc. to product structure, KA399C/07/a2

Содержание Tophit CPS471

Страница 1: ...ference system poisoning resistant polyacrylamide free gel Application possible at low temperatures Short response time Constantly high accuracy Sterilisable and autoclavable Longer calibration interv...

Страница 2: ...table sensor circuits use the dependence on the ion selective gate potential to create an output signal proportional to the concentration of the ion type pH selective IsFET The gate isolator serves as...

Страница 3: ...lues 0 09 and 13 86 a0003867 en Fig 3 Comparison of acid and alkaline errors Measurement stability and sensor response time The ISFET response times are very short over the whole temperature range Wit...

Страница 4: ...H value can be worked out from this equation isothermic curve potential change per pH value at a defined temperature The isothermic curves of the ISFET sensor are very close to the theoretical values...

Страница 5: ...mitter and used to calculate the current measured value Storing the calibration data in the sensor allows for calibration and adjustment away from the measuring point The result Sensors can be calibra...

Страница 6: ...sembly e g Cleanfit P CPA471 CPA450 with digital sensor only There are additional accessories available depending on the application Topclean S CPC30 or Topcal S CPC310 automatic cleaning system Exten...

Страница 7: ...tomatic measurement cleaning and calibration system CIP cleaning The sensor built into the retractable assembly is automatically moved out of the medium before cleaning In the rinse chamber of the ret...

Страница 8: ...mmersion assembly Dipfit W CPA111 3 Special measuring cable CPK12 or CYK10 4 Transmitter Liquiline Pharmaceuticals and biotechnology a0003877 Fig 8 Measuring system for pharmaceutical and biotechnolog...

Страница 9: ...ote The cable cors Yellow and White are connected on the sensor side Make sure you comply with the instructions for connecting the sensor wiring diagram in the Operating Instructions of the transmitte...

Страница 10: ...s Longer dry storage of the sensor up to 30 minutes Installation Installation angle ISFET sensors can be installed in any position as there is no liquid internal lead However in case of an overhead in...

Страница 11: ...he rotable plug in head When installing the sensor in an assembly use the engraved serial number on the connection head for correct sensor orientation The serial number is always located in the same p...

Страница 12: ...alibration and operation Normal environment light does not influence the measurement Process Medium temperature depending on pH At high temperatures over a long period of time alkalis irreversibly des...

Страница 13: ...en Fig 14 Pressure and temperature Caution Danger of damage to the sensor Never use the Tophit for applications outside the given specifications Recommended cleaning Depending on the degree of polluti...

Страница 14: ...acc to DIN IEC 751 Plug in head CPS471 ESB TOP68 rotatable CPS471D Memosens rotatable Diaphragm Ceramics sterilizable a0003903 Fig 15 Tophit CPS471 depending on the sensor version a0003904 Fig 16 Sens...

Страница 15: ...l EPDM Application range pH 0 to 14 15 to 135 C 5 to 275 F For Ex and Non Ex applications Product structure CPS471 Product structure CPS471D Shaft length 2 120 mm 4 72 in 4 225 mm 8 86 in 5 360 mm 14...

Страница 16: ...obtained are representative of the ISFET Sensor TopHit type CPS 471 and type CPS 441 Materials in contact with medium are FDA certified Certified acc to the 3 A standard no 74 02 Accessories Transmit...

Страница 17: ...iable process termination parts in contact with medium of PP PEEK or PVDF Technical Information TI345C 07 en Cleanfit H CPA475 Retractable assembly for tank and pipe installation under sterile conditi...

Страница 18: ...sheath max 130 C 266 F HC Cable length 15 m 49 23 ft TPE sheath max 130 C 266 F HD Cable length 20 m 65 64 ft TPE sheath max 130 C 266 F HF Cable length 5 to 20 m 16 41 to 65 64 ft TPE sheath max 130...

Страница 19: ...of e g Memosens CUS31 CUS41 2 wires twisted pair with shield and PVC sheath 2 x 2 x 0 5 mm2 shield Sold by the meter order no 51502543 Junction boxes Junction box VBA With 10 high impedance terminals...

Страница 20: ...TI283C 07 en 04 06 51506685 Printed in Germany FM SGML 6 0 DT...

Отзывы: