• Two closing contacts per tank. Protected by 2A fuses (replaceable)

• Min. current/voltage: 10 mA 10 V

• Max. current/voltage:

– UL: C 300

– AC-15: 1.5 A 250 V

AC

– DC-13: 2 A 24 V

DC

 (0.1 Hz)

Surge voltage resistance

2

 

500 V

Overvoltage category

(VDE 0110-1)
III

Power supply

Supply voltage

Voltage
range

90 to 132 V

AC

 (100 to 120 V auto-select input)

180 to 264 V

AC

 (200 to 240 V auto-select input)

Power
supply
frequency

50 to 60 Hz(+/- 6%)

Power
consumption

Depends on the type of Overfill Prevention System (AOPS, MOPS, SIL2, SIL3, options used etc.) and
the number of tanks
Max. at 230 V: 3 A
Max. at 115 V: 5 A

Max. back-
up fuse

16 A, tripping characteristic C

Electrical connection

Terminal strip (in cabinet, cable run from below)

Environment

Control cabinet:

Indoor installation (max. 25 °C), non-hazardous area

External text display unit:

Only indoors, non-hazardous area

Содержание SOP600

Страница 1: ...rformed periodically to maintain functional safety A corresponding report can be printed out on a printer optional The system offers an UPS optionally AOPS for 30 minute operation in the event of a po...

Страница 2: ...al connection 6 Environment 6 Ambient temperature range 7 Humidity 7 Degree of protection 7 Electromagnetic compatibility EMC 7 Mechanical construction 7 Certificates and approvals 9 CE mark 9 Ex appr...

Страница 3: ...is also signaled by the stack lights If the High level is exceeded this only causes a warning message to appear on the touch panel and text display unit and the stack lights signal A safety shutdown...

Страница 4: ...oes not take the customer s actuator valve pump into consideration A project specific calculation for the corresponding SIL circuit including actuators can be ordered as an option or can be performed...

Страница 5: ...iquiphant twin core screening is not mandatory Max length 1000 m 3281 ft For detailed information about the electrical connection of the device see the documentation of the Liquiphants 12 used FTL5x 7...

Страница 6: ...32 VAC 100 to 120 V auto select input 180 to 264 VAC 200 to 240 V auto select input Power supply frequency 50 to 60 Hz 6 Power consumption Depends on the type of Overfill Prevention System AOPS MOPS S...

Страница 7: ...robe field signaling 25 to 55 C 13 to 131 F Alarm siren field signaling 25 to 55 C 13 to 131 F Humidity Control cabinet 5 to 85 RH External text display unit 5 to 95 RH non condensating Alarm strobe f...

Страница 8: ...0x1200x300 BxHxD in mm for wall mounting approx 250 mm height for the signal lamps Cabinet for 12 tanks 1000x1200x300 BxHxD in mm double door for wall mounting approx 250 mm height for the signal lamp...

Страница 9: ...teel 1 5 mm Dipcoat primed RAL 7035 Terminals Different types of terminals standard multi tier and terminal blocks are mounted on the underside of the mounting plate Operating concept General Local co...

Страница 10: ...uidelines EC Low Voltage Directive 2014 35 EU IEC EN 60204 1 Safety of Machinery Electrical Equipment of Machines IEC 61508 Functional Safety of Electrical Electronic Programmable Electronic Safety re...

Страница 11: ...TL325P P1E1 FM AE FTL325P T1E1 CSA BA FTL825 AA3E4 NEx BB FTL825 CA3E4 CSA BC FTL825 N23E4 NEPSI BD FTL825 8B3E4 ATEX IECEx BE FTL825 8C3E4 FM CSA YY Special version TSP no to be spec 060 Analog signa...

Страница 12: ...ly with A21 A24 M21 M24 030 060 Possible future option 070 E F K only with AOPS 080 1 only available with A11 13 A21 22 M11 13 M21 22 030 2 only available with A11 23 M11 23 030 3 only available with...

Страница 13: ...Endress Hauser 13 Liquiphant M FTL7x Technical Information TI00354F 00 EN Brief Operating Instructions KA00143F 00 EN Overfill Prevention System SOP600 Operating Instructions BA01587S 04 EN Functional...

Страница 14: ......

Страница 15: ......

Страница 16: ...www addresses endress com...

Отзывы: