Smart System for Aquacultures SSP200B
Electrical connection
Hauser
23
6.5.3
Connecting the supply voltage for the Modbus Edge Device,
100 to 240 V AC
UNO PO
WER
DC OK
Output DC
24V 30W
L
N
Input AC
100V-240V
N
1
1
2
3
L
2 3
PE
A0037821
20
Connecting supply voltage 100 to 240 V AC
1
Terminal blocks
2
Cable entry
3
Power supply cable
1. Route the power supply cable into the housing through the cable gland at
connection
port G
.
2. Connect the protective ground to the green/yellow terminal strip "1".
3. Connect the neutral conductor N to the blue terminal strip "2".
4. Connect phase L to the gray terminal strip "3".
5. Close the housing → 17.