5.11.3 Anchor weight method
This method secures a temperature probe using an anchor weight.
The temperature probe can be damaged. Ensure that it does not hit a corner if it is being
inserted from the installation nozzle.
1
2
3
4
5
6
8
7
1
2
3
5
6
8
7
400 (15.75)
400 (15.75)
200
(7.87)
500 (19.69)
500 (19.69)
!
(1.
27.2
07)
!
(
42 1.65)
1.
A
1.
B
A0042757
25
Anchor weight method. Unit of measurement mm (in)
A
Without WB probe
B
With WB probe
1
Converter (electrical compartment)
2
Flange
3
Top element
4
WB probe
5
Bottom element
6
Anchor weight (high profile)
7
Temperature probe
8
Anchor weight (low profile)
L
CAUTION
Installation of an anchor weight
Using an anchor weight that is heavier than 6 kg (13.23 lb) may cause internal damage to
the temperature probe.
‣
Ensure that the anchor weight is stable at the bottom of the tank. When installing
NMT81 with a suspended anchor weight, use an anchor weight that weighs 6 kg
(13.23 lb) or less.
Anchor weight installation procedure
1. Tie the bottom hook of the temperature probe or the WB probe to the anchor
weight's ring using a tension wire.
2. Wrap the tension wire twice around the bottom hook. Pull it downwards and tie it
down, and then bundle it with the provided securing wire.
3. Using bolts, secure the flange of NMT81 to the nozzle at the top of the tank.