background image

Promonitor NRF560

30

Hauser

10

Troubleshooting

If an error occurs in the Proservo NMS5, or the Promonitor NRF560, your current matrix and error message 
will blink alternately in the Promonitor NRF560’s LDC screen. 
Controls relevant to the display are operative even while an error message is displayed. 

LOCAL ERROR: NMT

No communication with the

Promonitor NRF560, Prothermo
NMT532/539 series.

LOCAL ERROR: DEV1 (or 2)

No communication with the

HART

device 1 (or 2).

DEVICE ERROR: NMS

The Prosevo NMS5 gives an 
error signal.

DEVICE ERROR: NMT

The Prothermo NMT532/539 gives an

err or signal.

DEVICE ERROR: DEV 1 (or 2)

device 1 (or 2) gives

an err or signal.

OVER TENSION

tension error.

UNDER WEIGHT

 tension error. 

Z PHASE NO INPUT

Check data of EEPROM

Consult E+H Service.

Consult E+H Service.

R

R

R

R

Message

Cause

Remedy

The HART

The Proservo NMS5 gives over

The Proservo NMS5 gives under

The Proservo NMS5 gives Z phase 
no input error

SIFA ERROR

The Proservo NMS5 gives SIFA error.

ROM ERROR

POWER FAILURE

The supply voltage has dropped.

RAM FAILURE

The data of the RAM are illegal.

Check the power supply.

Check the Proservo NMS5.
Replace the CPU board of the 
Proservo NMS5.

Check the Proservo NMS5.
Replace the detector unit of 
the Proservo NMS5. 

Check if the measuring wire is cut
or the displacer is lost.

Check if the displacer motion is 
blocked by clogging or sticking

Check the HART    device 1 (or 2). 

Check the diagnosis of the Prothermo
NMT532/539

Check the diagnosis of the
Proservo NMS5.

Check the connection and setting of 
the HART

device 1 (or 2).

Check the HART

R

device 1 (or 2).

Check the connection and setting of 
the Prothermo NMT532/539.

NMS COMM ERR

No communication with the Proservo 
NMS5

Check the connection and setting of 
the Proservo NMS5 to 
the Promonitor NRF560 

10 Troubleshooting

Содержание Promonitor NRF560

Страница 1: ...BA00425G 08 EN 02 12 71201677 Valid as of Software Version V 1 94 Operating Instructions Promonitor NRF560 Tank Side Monitor...

Страница 2: ...ng status and can send operating commands to the Proservo NMS5 from a convenient location Ptomonitor NRF560 is operated by three visual operating elements namely the keys E and Local HART Power AC DC...

Страница 3: ...ation variants 13 4 Wiring 15 4 1 Connection Procedure 15 4 2 Input 16 4 3 Cable Gland 16 5 Operation 17 5 1 Display and Operating Elements 17 5 2 Functions of the operating Elements 18 5 3 Programmin...

Страница 4: ...instructions before carrying out the procedures The instrument may only be operated by personnel who are authorized and trained by the operator of the facility All instructions in this manual are to...

Страница 5: ...located in and wiringentering areas with the designation explosion hazardous areas must conform with the stated type of protection Safe area non explosion hazardous area Symbol used in drawings to ind...

Страница 6: ...BAL is present Certification no Tank ID PROMONITOR NRF560 0044 Made in Japan Yamanashi 406 0846 Endress Hauser Yamanashi Co Ltd Warning Do not open the cover when energized 1 2 3 4 5 6 7 8 9 Order Co...

Страница 7: ...l when indication BAL is present Cetification no Tank ID Order code Ser no Ex proof model Protection class 30 70 Warning After de energizing delay 30 sec before opening the cover Use heat resistant ca...

Страница 8: ...216422 PROMONITOR NRF560 Ambient temperature 20 60 Warning Keep cover tight while circuits are alive Caution Use supply wires suitable for 70 minimum Caution A seal shall be installed within 50 mm of...

Страница 9: ...ECEx Ex d IIC T4 Gb 9 Special version TSP no to be spec 020 Cable Entry A 2x thread G1 2 B 2x thread NPT1 2 D 2x thread M20 Y Special version TSP no to be spec 030 Power Supply 3 85 264VAC 50 60Hz 4 2...

Страница 10: ...erate The instrument complies with the applicable standards and regulations in accordance with EN 50014 Electrical apparatus for potentially explosive atmospheres General requirements The instrument d...

Страница 11: ...ches your order 3 1 2 Transport Caution Follow the safety instructions and transport conditions for instruments of more than 18 kg Do not lift the mea suring instrument by its housing in order to tran...

Страница 12: ...Use the appropriate cable gland and tighten it firmly Warning For the mounting of the Promonitor NRF 560 make sure that the ambient temperature does not exceed the limit 229 179 172 70 123 111 150 105...

Страница 13: ...hout mounting bracket When attaching and bending the flexible tube the radius of curvature must be at least 300 mm 11 8 at any bend portion 3 3 1 Wall mounting Note After removal of the cover the disp...

Страница 14: ...n or there is a pipe on the tank side from the start select mounting on pipe Customer has to prepare 50mm U bolt Mouting braket for NRF has hole processing to mount 50mm U bolt Cable gland Flexible tu...

Страница 15: ...s to each terminal We recommend a crimped connection After completing all electric connections screw the terminal cover and hook its lock shroud During the installation take care of mounting the condu...

Страница 16: ...ment For local HART communications cable use a shielded twisted paired cable The number of cable cores is 2C for power supply and 1P for local HART communications 4 3 Cable Gland Caution Promonitor NR...

Страница 17: ...nt programming matrix 5 1 2 Operating elements The Promonitor NRF560 is operated by three visual operating elements namely the keys E and They are activated when the appropriate field on the protectiv...

Страница 18: ...finger from the touch control then the procedure will start again from the minimum digit Analogy of mechanical counter Key Function Access to the programming matrix touching the key for more than 3 s...

Страница 19: ...rface level measurement Tank bottom measurement Operating for NMS5 is available using access code 50 Note Promonitor NRF560 access code is 50 only LCD HOME position If you touch E for 3 seconds or lon...

Страница 20: ...ed at Proservo NMS5 in order to display Promonitor NRF560 data on Proservo NMS5 screens Note Power on NMS5 in first Security level Access code 0 none 1 For Operator 50 For Engineer Security level Acce...

Страница 21: ...touching once you reach 50 4 50 is blinking Gently touch again to increase the second digit from 0 to 1 Now you have 51 5 Here touch E EDITING ENABLED will be displayed Note 1 When you touch E while d...

Страница 22: ...ting at the reference position UP The UP command has been given STOP The STOP command has been given LIQU The Proservo NMS5 is measuring the surface level U IF The Proservo NMS5 is measuring the upper...

Страница 23: ...displacer is resting on the liquid surface or interface and in bal anced status T B Temporary Balance Automatic weight calibration is being carried out U U Unbalance Up The displacer is being hoisted...

Страница 24: ...matrix functions are available In the table H stands for horizontal row and V for vertical column NRF560 programing matrix static matrix Group massage H V 0 1 2 3 4 5 6 7 8 9 Operation Display Operat...

Страница 25: ...on by pressing E Enter Select Varies the display contrast in 16 steps Shows the Promonitor NRF560 s control software version Set 000 011 013 Display OFF Display LEVEL Phase16 010 The contrast can be a...

Страница 26: ...splay 0 0 mm 0 0 mm UPPER INTERF LEV Display DEV 2 Display Display UNBALANCED BALANCING STATUS Display MIDD INTERF LEV Display Display BOTTOM LEVEL 0 0 mm 0 0 C GAS TEMPERATURE LEVEL LEVEL OPERAT BY N...

Страница 27: ...N HYSTER MODE ON Select 51 OFF CONNECTION NMT SPOT TEMP AVERAGE TEMP Select 51 DRUM SETTING ON Select 51 OFF WEIGHT CALIBR 145 0 ml DISPLACER VOLUM 0 999 9 Set 51 0 999 9 Set 51 BALANCE VOLUME 60 ml 1...

Страница 28: ...parts Please contact Endress Hauser Service for further information on service and spare parts Repairs to Ex approved devices When carrying out repairs to Ex approved devices please note the followin...

Страница 29: ...racket Note U bolt is not attached to the mounting bracket If you need U bolt please contact Endress Hauser 150 approx 40 12 4 holes 110 74 30 200 approx 30 74 M10 approx 85 Example of U bolt with use...

Страница 30: ...ssage Cause Remedy The HART The Proservo NMS5 gives over The Proservo NMS5 gives under The Proservo NMS5 gives Z phase no input error SIFA ERROR The Proservo NMS5 gives SIFA error ROM ERROR POWER FAIL...

Страница 31: ...tained in kits Spare parts which you can order from Endress Hauser for the Promonitor are shown with their order numbers in the diagram below For more information on service and spare parts contact En...

Страница 32: ...luminium 35 Noise filter 017801 0133 Cover terminal box Alu 017801 0020 Filter board spacer 85 260VAC 31 Electronic module power module 36 Chassis 70103940 POW 6 HV nonEx i 71070911 Chassis EMC filter...

Страница 33: ...ng instructions if necessary for example a safety data sheet as per EN 91 155 EEC Additionally specify An exact description of the application The chemical and physical characteristics of the product...

Страница 34: ...n each Ex approval Refer to the designated certification Power consumption Maximum 25 VA Arrester Standard equipment Ambient temperature range 20 60 C 4 140 F standard Note the LCD could not be seen b...

Страница 35: ...__________________________________________ ______________________________________________________________________________________________________________ We hereby certify that this declaration is fil...

Страница 36: ...02 12 71201677 FM SGML 8 0J Endress Hauser Japan Co Ltd Product Center Yamanashi 862 1 Mitsukunugi Sakaigawa cho Fuefuki shi Yamanashi 406 0846 Japan Phone 81 55 266 4964 Fax 81 55 266 4969 www endres...

Отзывы: