Proline t-mass 65F, 65I
Hauser
33
Transducer elements:
• 1.4404 to EN10217-7 / 316L SS to A249 or
• 1.4404 to EN 10216-5 / 316L SS to A213
• Alloy C22 and UNS N06022 to B626
O-ring seals:
EPDM, Kalrez, Viton
t-mass I sensor:
Insertion tube:
Sensor length 235 (9"), 335 (13"), 435 (17"), 608 (24"):
1.4404 to EN 10216-5 and 316/316L SS to A312
Transducer body:
• 1.4404 to EN10272 and 316L SS to A479
• Alloy C22 and UNS N06022 to B574
Transducer elements:
• 1.4404 to EN10217-7 / 316L SS to A249 or
• 1.4404 to EN 10216-5 / 316L SS to A213
• Alloy C22 and UNS N06022 to B626
Compression fitting:
1.4404 to EN 10272 and 316/316L SS to A479
Compression fitting seal:
PEEK
Bonded seals:
EPDM, Kalrez, Nitrile
316/316L SS (outer ring)
Low pressure retractable insertion fitting (Cold tap):
Lower tube section:
1.4404 to EN 10272 and 316/316L SS to A479
Upper tube section:
1.4404 to EN 10216-5 and 316/316L SS to A312
Ball valve:
1.4408 to EN 10213-4 and CF8M
Seal:
PTFE
Process connections
t-mass F:
Flanges according EN 1092-1, JIS B2238 and ANSI B16.5
t-mass I:
G 1A or 1" MNPT thread
Note!
For both the flanged and insertion meters it is possible to have wetted parts degreased for oxygen service.
Contact your Hauser service representative for further details.