Brief Operating Instructions

Proline Promass

Part 1 of 2

Coriolis sensor

These Instructions are Brief Operating Instructions; they are

not a substitute for the Operating Instructions pertaining to

the device.
These Brief Operating Instructions contain all of the

information on the sensor. Please also follow the Brief

Operating Instructions for the transmitter during

commissioning →   3.

KA01212D/06/EN/03.17

71360078

Содержание Proline Promass series

Страница 1: ...are Brief Operating Instructions they are not a substitute for the Operating Instructions pertaining to the device These Brief Operating Instructions contain all of the information on the sensor Pleas...

Страница 2: ...Proline Promass 2 Endress Hauser 1 Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 2 3 A0023555...

Страница 3: ...ification Storage and transport Installation Transmitter Brief Operating Instructions The Transmitter Brief Operating Instructions are aimed at specialists with responsibility for commissioning config...

Страница 4: ...ty 8 2 5 Product safety 8 2 6 IT security 9 3 Incoming acceptance and product identification 9 3 1 Incoming acceptance 9 3 2 Product identification 10 4 Storage and transport 11 4 1 Storage conditions...

Страница 5: ...ontains information on procedures and other facts which do not result in personal injury 1 1 2 Symbols for certain types of information Symbol Meaning Symbol Meaning Permitted Procedures processes or...

Страница 6: ...symbols Symbol Meaning Symbol Meaning Wireless Local Area Network WLAN Communication via a wireless local network Bluetooth Wireless data transmission between devices over a short distance LED Light...

Страница 7: ...the nameplate To ensure that the measuring device remains in proper condition for the operation time Only use the measuring device in full compliance with the data on the nameplate and the general co...

Страница 8: ...g to be exceeded This can lead to rupture or failure of the sensor housing 2 3 Workplace safety For work on and with the device Wear the required personal protective equipment according to federal nat...

Страница 9: ...any inadvertent changes to the device settings IT security measures in line with operators security standards and designed to provide additional protection for the device and device data transfer must...

Страница 10: ...ery The Technical Documentation is available via the Internet or via the Endress Hauser Operations App 3 2 Product identification The following options are available for identification of the measurin...

Страница 11: ...ce 4 Storage and transport 4 1 Storage conditions Observe the following notes for storage Store in the original packaging to ensure protection from shock Do not remove protective covers or protective...

Страница 12: ...of injury if the measuring device slips Secure the measuring device against slipping or turning Observe the weight specified on the packaging stick on label A0029214 4 2 2 Measuring devices with lift...

Страница 13: ...the construction of the device 5 1 1 Mounting position Mounting location A0028772 Installation in down pipes However the following installation suggestion allows for installation in an open vertical...

Страница 14: ...ons 1 Supply tank 2 Sensor 3 Orifice plate pipe restriction 4 Valve 5 Batching tank DN orifice plate pipe restriction mm in mm in 1 0 8 0 03 2 1 5 0 06 4 3 0 0 12 8 6 0 24 15 10 0 40 15 FB FB 15 0 60...

Страница 15: ...on transmitter at top A0015589 1 Exceptions 3 16 C Horizontal orientation transmitter at bottom A0015590 2 Exceptions 3 16 D Horizontal orientation transmitter at side A0015592 3 4 5 1 Applications wi...

Страница 16: ...T pieces as long as no cavitation occurs 17 A0029322 A0029323 For the dimensions and installation lengths of the device see the Technical Information document Mechanical construction section 5 1 2 Req...

Страница 17: ...hermal insulation Observe maximum permitted insulation height of the transmitter neck so that the transmitter head is completely free NOTICE Danger of overheating with insulation Ensure that the tempe...

Страница 18: ...ded insulation thickness depending on the temperature of the medium and the ambient temperature Maximum recommended insulation thickness depending on the medium temperature and ambient temperature for...

Страница 19: ...19 0 20 60 40 80 in 1 2 3 0 t 100 4 mm t40 104 t60 140 80 100 120 140 200 300 160 F Tm C A0029981 5 Valid for Promass I S 0 20 60 40 80 in 1 2 3 0 t 100 4 mm t40 104 t60 140 80 100 120 140 200 300 16...

Страница 20: ...H O P Q 0 20 60 40 80 in 1 2 3 0 t 100 4 mm t40 104 t60 140 80 100 120 140 200 300 400 160 180 200 F Tm C 220 240 A0028906 8 Valid for Promass F t Insulation thickness Tm Medium temperature T40 104 M...

Страница 21: ...60 600 400 A0029903 t Insulation thickness Tm Medium temperature t40 104 Maximum recommended insulation thickness at an ambient temperature of Ta 40 C 104 F t60 140 Maximum recommended insulation thic...

Страница 22: ...ng Heating options If a fluid requires that no heat loss should occur at the sensor users can avail of the following heating options Electrical heating e g with electric band heaters Via pipes carryin...

Страница 23: ...TURE DISK i 2 3 1 DN 8 150 6 DN 250 10 2 3 A0028903 1 Rupture disk label 2 Rupture disk with 1 2 NPT internal thread with 1 width across flat 3 Transport protection For information on the dimensions s...

Страница 24: ...y monitored RUPTURE DISK i 1 A0030005 Promass X Make sure that the function and operation of the rupture disk is not impeded through the installation of the device The position of the rupture disk is...

Страница 25: ...echanical construction section of the Technical Information document Securing with mounting clamps for hygiene connections Promass I P S It is not necessary to provide additional support for the senso...

Страница 26: ...0 40 668 26 3 28 1 1 60 2 36 40 FB 40 FB 780 30 71 35 1 38 80 3 15 50 50 780 30 71 35 1 38 80 3 15 50 FB 50 FB 1152 45 35 57 2 24 90 3 54 80 80 1152 45 35 57 2 24 90 3 54 Complete drainability guarant...

Страница 27: ...or 21 mm m 0 24 in feet 4 Line on the underside indicates the lowest point of the eccentric process connection Promass P 1 4 3 1 2 5 A0016583 1 Eccentric clamp connection 2 This side up label indicate...

Страница 28: ...he floor wall or ceiling Support the sensor on a securely mounted support base e g angle bracket The following mounting versions are recommended for the installation Vertical Mounted directly on a wal...

Страница 29: ...es place under reference conditions Therefore a zero point adjustment in the field is generally not required Experience shows that zero point adjustment is advisable only in special cases To achieve m...

Страница 30: ...esent from the sensor 3 If present remove transport protection of the rupture disk 4 Remove stick on label on the electronics compartment cover 5 2 3 Mounting the measuring device LWARNING Danger due...

Страница 31: ...ecipitation and direct sunlight Are the securing screw and securing clamp tightened securely 6 Disposal 6 1 Removing the measuring device 1 Switch off the device LWARNING Danger to persons from proces...

Страница 32: ...www addresses endress com...

Отзывы: