Proline Promag P 100

Operation options

Hauser

39

1

2

3

  A0021270

 17

Connection for order code for "Output", option L: PROFIBUS DP

1

Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

2

Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or
with "FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"

3

Standard Ethernet connecting cable with RJ45 plug

1

2

3

  A0016940

 18

Connection for order code for "Output", option N: EtherNet/IP

1

Service interface (CDI -RJ45) and EtherNet/IP interface of the measuring device with access to the
integrated Web server

2

Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or
with "FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"

3

Standard Ethernet connecting cable with RJ45 plug

Содержание Proline Promag P 100

Страница 1: ...hese Instructions are Brief Operating Instructions they do not replace the Operating Instructions included in the scope of supply For detailed information refer to the Operating Instructions and other...

Страница 2: ...ons 14 6 2 Mounting the measuring device 19 6 3 Post installation check 20 7 Electrical connection 21 7 1 Connection conditions 21 7 2 Connecting the measuring device 25 7 3 Hardware settings 29 7 4 E...

Страница 3: ...rical symbols Symbol Meaning A0011197 Direct current A terminal to which DC voltage is applied or through which direct current flows A0011198 Alternating current A terminal to which alternating voltag...

Страница 4: ...at are preferred A0011184 Forbidden Indicates procedures processes or actions that are forbidden A0011193 Tip Indicates additional information A0011194 Reference to documentation Refers to the corresp...

Страница 5: ...ending on the version ordered the measuring device can also measure potentially explosive flammable poisonous and oxidizing media Measuring devices for use in hazardous areas in hygienic applications...

Страница 6: ...of the electronic components Hot process fluids passing through the measuring device will further increase the surface temperature of the housing The surface of the sensor in particular can reach tem...

Страница 7: ...ity We only provide a warranty if the device is installed and used as described in the Operating Instructions The device is equipped with security mechanisms to protect it against any inadvertent chan...

Страница 8: ...duct description 3 1 Product design 3 1 1 Device version with HART Modbus RS485 and PROFIBUS DP communication types 2 3 4 1 A0017609 1 Important components of a measuring device 1 Transmitter housing...

Страница 9: ...ser 9 3 1 2 Device version with EtherNet IP communication type 2 3 4 5 1 A0017257 2 Important components of a measuring device 1 Transmitter housing cover 2 I O electronics module for EtherNet IP 3 Ma...

Страница 10: ...ance and product identification Proline Promag P 100 10 Endress Hauser 4 Incoming acceptance and product identification 4 1 Incoming acceptance A0015502 1 2 1 2 A0013843 A0013695 A0015502 A0013698 A00...

Страница 11: ...numbers from nameplates in W M Device Viewer www endress com deviceviewer All information about the measuring device is displayed For an overview of the scope of the Technical Documentation provided r...

Страница 12: ...WARNING Center of gravity of the measuring device is higher than the suspension points of the webbing slings Risk of injury if the measuring device slips Secure the measuring device from rotating or...

Страница 13: ...Proline Promag P 100 Storage and transport Endress Hauser 13 A0015604 A0015605...

Страница 14: ...Mounting location h 2 DN h A0017061 Installation in down pipes Install a siphon or a vent valve downstream of the sensor in down pipes whose length h 5 m 16 4 ft This precaution is to avoid low pressu...

Страница 15: ...ps you to install the sensor according to the flow direction An optimum orientation position helps avoid gas and air accumulations and deposits in the measuring tube Vertical This is the optimum orien...

Страница 16: ...s 5 DN 2 DN A0016275 For the dimensions and installation lengths of the device see the Technical Information document Mechanical construction section 6 1 2 Requirements from environment and process Am...

Страница 17: ...itions Temperature tables SI units Ta C T6 85 C T5 100 C T4 135 C T3 200 C T2 300 C T1 450 C 30 50 95 130 150 150 150 50 95 130 150 150 150 60 95 110 110 110 110 US units Ta F T6 185 F T5 212 F T4 275...

Страница 18: ...omag P 100 18 Endress Hauser Vibrations L A0016266 6 Measures to prevent vibration of the device L 10 m 33 ft Adapters 100 10 0 5 d D mbar 0 6 0 7 0 8 0 9 1 m s 2 m s 3 m s 4 m s 5 m s 6 m s 7 m s 8 m...

Страница 19: ...Danger due to improper process sealing Ensure that the inside diameters of the gaskets are greater than or equal to that of the process connections and piping Ensure that the gaskets are clean and un...

Страница 20: ...torques For detailed information on the screw tightening torques see the Mounting the sensor section of the Operating Instructions for the device 6 3 Post installation check Is the device undamaged vi...

Страница 21: ...ing cables provided by the customer must fulfill the following requirements Electrical safety In accordance with applicable federal national regulations Permitted temperature range 40 C 40 F to 80 C 1...

Страница 22: ...pacitance 30 pF m Wire cross section 0 34 mm2 22 AWG Cable type Twisted pairs Loop resistance 110 km Signal damping Max 9 dB over the entire length of the cable cross section Shielding Copper braided...

Страница 23: ...th pulse frequency switch output 4 20 mA HART with pulse frequency switch output on the device side 3 2 4 1 5 A0016810 Pin Assignment Coding Plug socket 1 4 20 mA HART active A Socket 2 4 20 mA HART a...

Страница 24: ...on protection Personal protection equipment National installation regulations and guidelines Observe cable specification 21 Keep the stripped and twisted lengths of cable shield to the ground terminal...

Страница 25: ...red with cable glands Observe cable specification 21 7 2 Connecting the measuring device NOTICE Limitation of electrical safety due to incorrect connection For use in potentially explosive atmospheres...

Страница 26: ...upply voltage Connect the cable in accordance with the terminal assignment or the device plug pin assignment 23 7 2 2 Ensuring potential equalization CAUTION Electrode damage can result in the complet...

Страница 27: ...measuring tube Connection example in special situations Unlined and ungrounded metal pipe This connection method also applies in situations where The customary potential equalization is not used Equal...

Страница 28: ...d terminal and ground disks Ground cable Copper wire at least 6 mm2 0 0093 in2 Pipe with a cathodic protection unit This connection method is only used if the following two conditions are met Metal pi...

Страница 29: ...4th octet 192 168 1 XXX Can only be configured via software addressing Can be configured via software addressing and hardware addressing IP address range 1 to 254 4th octet IP address broadcast 255 Ad...

Страница 30: ...ivered from the factory with the device address 126 and with the software addressing method Setting the address OFF ON 1 2 3 4 5 6 7 8 9 10 1 2 4 8 16 32 64 Write protection Not used PROFIBUS address...

Страница 31: ...sure that an external bus terminator is used It is generally advisable to use an external bus terminator as the entire segment can fail if a device that is terminated internally is defective 390 DIP 1...

Страница 32: ...measuring device fulfills all the requirements for the IP66 67 degree of protection Type 4X enclosure To guarantee IP66 67 degree of protection Type 4X enclosure carry out the following steps after th...

Страница 33: ...tch the specifications on the transmitter nameplate For device version with Modbus RS485 intrinsically safe does the supply voltage match the specifications on the nameplate of the Safety Barrier Prom...

Страница 34: ...y The individual parts of the operating menu are assigned to certain user roles Each user role corresponds to typical tasks within the device lifecycle For detailed information about the operating phi...

Страница 35: ...ructure starts in the Web browser 8 2 3 Establishing a connection Configuring the Internet protocol of the computer The following information refers to the default Ethernet settings of the device IP a...

Страница 36: ...ce 1 2 OK A0017362 1 Device tag 42 2 Picture of device 8 2 4 Logging on Access code 0000 factory setting can be changed by customer 43 8 2 5 User interface 2 4 6 5 1 3 2 4 6 5 1 3 2 4 6 5 1 3 2 4 6 5...

Страница 37: ...file Export parameter settings csv file create documentation of the measuring point Export the Heartbeat verification log PDF file only available with the Heartbeat Verification application package U...

Страница 38: ...rface CDI RJ45 1 2 3 A0016926 16 Connection for the order code for Output option B 4 20 mA HART pulse frequency switch output 1 Service interface CDI RJ45 of the measuring device with access to the in...

Страница 39: ...FieldCare operating tool with COM DTM CDI Communication TCP IP 3 Standard Ethernet connecting cable with RJ45 plug 1 2 3 A0016940 18 Connection for order code for Output option N EtherNet IP 1 Servic...

Страница 40: ...COM DTM CDI Communication TCP IP 5 Ethernet switch 8 3 4 Establishing a connection For device version with EtherNet IP communication type Via service interface CDI RJ45 and FieldCare operating tool 1...

Страница 41: ...elect the desired device from the list and press OK to confirm 6 Establish the online connection to the device For details see Operating Instructions BA00027S and BA00059S 9 System integration For sys...

Страница 42: ...ion then the first three octets of the software address are retained If the IP address of the device is not known the device address currently configured can be read out Operating Instructions for the...

Страница 43: ...h the customer specific access code access to the measuring device via the Web browser is protected as are the parameters for the measuring device configuration Navigation Setup menu Advanced setup Ad...

Страница 44: ...nal temperature Reference density All parameters for configuring the totalizer The parameter values are now read only and cannot be edited any more Via service interface CDI Via HART protocol Via Modb...

Страница 45: ...15 For device version with PROFIBUS DP communication type OFF ON 1 2 3 4 5 6 7 8 9 10 1 2 4 8 16 32 64 Write protection Not used PROFIBUS address Software addressing A0021262 Setting the write protect...

Страница 46: ...ion has been established and on the home page of the web browser once the user has logged on Remedial measures are provided for each diagnostic event to ensure that problems can be rectified quickly W...

Страница 47: ......

Страница 48: ...www addresses endress com...

Отзывы: