Proline Promag 50H, 53H
Hauser
41
Clamp DIN 32676
Sensor
Fits to
di
G
D
L
LK
1.4404 / 316L
5*H**-0***********
DN
[mm]
Piping
DIN 11850
[mm]
[mm]
[mm]
[mm]
[mm]
A0005539
40
42 × 2
38
50.5
92
61.5
71.0
50
54 × 2
50
64.0
105
61.5
83.5
65
70 × 2
66
91.0
121
68.0
100.0
80
85 × 2
81
106.0
147
68.0
121.0
100
104 × 2
100
119.0
168
68.0
141.5
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Tri-Clamp L14 AM7
Sensor
Fits to
di
G
D
L
LK
1.4404 / 316L
5*H**-1***********
DN
[mm]
DN
[inch]
Piping
OD
[mm]
[mm]
[mm]
[mm]
[mm]
A0005543
40
1½"
38.1 × 1.65
34.8
50.4
92
68.8
71.0
50
2"
50.8 × 1.65
47.5
63.9
105
68.8
83.5
65
–
63.5 × 1.65
60.2
77.4
121
68.8
100.0
80
3"
76.2 × 1.65
72.9
90.9
147
68.8
121.0
100
4"
101.6 × 1.65
97.4
118.9
168
68.8
141.5
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling SC DIN 11851
Sensor
Fits to
di
G
D
L
LK
1.4404 / 316L
5*H**-2***********
DN
[mm]
Piping
DN 11850
[mm]
[mm]
[mm]
[mm]
[mm]
A0005540
40
42 × 2
38
Rd 65 × 1/6"
92
72
71.0
50
54 × 2
50
Rd 78 × 1/6"
105
74
83.5
65
70 × 2
66
Rd 95 × 1/6"
121
78
100.0
80
85 × 2
81
Rd 110 × 1/6"
147
83
121.0
100
104 × 2
100
Rd 130 × 1/6"
168
92
141.5
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling DIN 11864-1
Sensor
Fits to
di
G
D
L
LK
Aseptic threaded adapter, Form A
1.4404 / 316L
5*H**-3***********
DN
[mm]
Piping
DN 11850
[mm]
[mm]
[mm]
[mm]
[mm]
A0005545
40
42 × 2
38
Rd 65 × 1/6"
92
71
71.0
50
54 × 2
50
Rd 78 × 1/6"
105
71
83.5
65
70 × 2
66
Rd 95 × 1/6"
121
76
100.0
80
85 × 2
81
Rd 110 × 1/6"
147
82
121.0
100
104 × 2
100
Rd 130 × 1/6"
168
90
141.5
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
G
di
LK
D
L
G
di
LK
D
L
L
G
di
D
LK
L
G
di
D
LK
Содержание Proline Promag 50H
Страница 50: ...Proline Promag 50H 53H 50 Endress Hauser ...
Страница 51: ...Proline Promag 50H 53H Endress Hauser 51 ...