background image

TI082D/06/en/03.09
71088671

Technical Information

Proline Promag 50D

Electromagnetic flow measuring system
Flow measurement of liquids in water or wastewater applications

Application

Electromagnetic flowmeter for bidirectional 
measurement of liquids with:
• A minimum conductivity of 

≥ 

μ

S/cm

– Drinking water
– Wastewater

• Flow measurement up to 10 m³/min

• Fluid temperature up to +60 °C

• Process pressures up to 16 bar

• Polyamide lining material

• Drinking water approvals:

– KTW/W270
– WRAS BS 6920
– ACS
– NSF  61

Your benefits

The measuring devices offer you cost-effective flow 
measurement with a high degree of accuracy for a wide 
range of process conditions.

The uniform Proline transmitter concept comprises:
• High level of efficiency thanks to modular device 

concept

• High degree of reliability and measuring stability
• Uniform operating concept

The tried-and-tested Promag sensors offer:
• No pressure loss
• Not sensitive to vibrations
• Simple installation and commissioning
• Compact design

Содержание Proline Promag 50D

Страница 1: ...s pressures up to 16 bar Polyamide lining material Drinking water approvals KTW W270 WRAS BS 6920 ACS NSF 61 Your benefits The measuring devices offer you cost effective flow measurement with a high d...

Страница 2: ...ng cable 16 Operating conditions Environment 17 Ambient temperature range 17 Storage temperature 17 Degree of protection 17 Shock and vibration resistance 17 Electromagnetic compatibility EMC 17 Opera...

Страница 3: ...by means of the pipe cross sectional area The DC magnetic field is created through a switched direct current of alternating polarity a0003191 Ue B L v Q A v Ue Induced voltage B Magnetic induction mag...

Страница 4: ...constant can be selected 0 01 to 100s Full scale value adjustable Temperature coefficient typ 0 005 o r C resolution 0 5 A o r of reading Pulse frequency output Galvanically isolated Passive 30 V DC...

Страница 5: ...s model Promag 33 Bus address adjustable via miniature switches or local display optional at the measuring device Signal on alarm Current output Failsafe mode can be selected e g in accordance with NA...

Страница 6: ...bus Terminal 26 DP A PA PA with reverse polarity protection Terminal 27 DP B PA PA with reverse polarity protection e Ground terminal for signal cable fieldbus cable f Service connector for connecting...

Страница 7: ...US DP 85 to 260 V AC 45 to 65 Hz 20 to 55 V AC 45 to 65 Hz 16 to 62 V DC PROFIBUS PA Non Ex 9 to 32 V DC Ex i 9 to 24 V DC Ex d 9 to 32 V DC Order version Terminal No 20 21 22 23 24 25 26 27 1 L1 L 2...

Страница 8: ...ded cores Conductor resistance 50 km Capacitance core shield 420 pF m Operating temperature 20 to 80 C Cable cross section max 2 5 mm2 16 AWG a0003194 a Signal cable b Coil current cable 1 Core 2 Core...

Страница 9: ...minal of the transmitter When using the measuring device in a Metal pipe that is not grounded This connection method also applies in situations where Customary potential equalization cannot be ensured...

Страница 10: ...Inlet run 10 x DN Outlet run 5 x DN Sensor and transmitter grounded The sensor is centered in the pipe Maximum measured error Current output also typically 5 A Pulse output 0 5 o r 1 mm s o r of read...

Страница 11: ...ing correctly a0010705 Mounting location Installation with pumps The sensor should only be installed on the pump pressure side Note The sensor should never be installed on the pump suction side in ord...

Страница 12: ...essure tightness of the measuring tube can be found in the Pressure tightness section in the Operating conditions Process chapter a0010708 Installation measures for down pipes h 5 m 1 Vent valve 2 Pip...

Страница 13: ...can be found in the Shock and vibration resistance section in the Operating conditions Environment chapter a0010711 en Measures to prevent vibration of the measuring device Inlet and outlet run If po...

Страница 14: ...an be used to calculate the pressure loss caused by reducers and expanders Note The nomogram only applies to liquids of viscosity similar to water The pressure loss is calculated as follows 1 Calculat...

Страница 15: ...ering sleeves are also provided depending on the flange standard or the diameter of the pitch circle Note A mounting kit consisting of mounting bolts seals nuts and washers can be ordered separately s...

Страница 16: ...of electrical machines and switching elements If necessary establish potential equalization between the sensor and transmitter The permitted cable length Lmax is determined by the fluid conductivity A...

Страница 17: ...uid temperatures are high Storage temperature Sensor 20 to 60 C Transmitter 20 to 60 C Caution The measuring device must be protected against direct sunlight during storage in order to avoid unaccepta...

Страница 18: ...flow velocity is between 2 and 3 m s The velocity of flow v moreover has to be matched to the physical properties of the fluid v 2 m s in the case of fluids that cause buildup such as wastewater sludg...

Страница 19: ...m DN inch L A B C d 1 d 2 e 1 e 2 EN DIN JIS ANSI mm mm mm mm mm mm max Seals mm 25 1 55 283 240 43 86 24 68 40 1 69 303 251 52 104 38 87 50 2 83 324 262 62 124 50 105 80 117 351 276 75 151 76 138 3 1...

Страница 20: ...B C d 1 d 2 e 1 e 2 EN DIN JIS ANSI mm mm mm mm mm mm max Seals mm 25 1 55 235 192 43 86 24 68 40 1 69 255 203 52 104 38 87 50 2 83 276 214 62 124 50 105 80 117 303 228 75 151 76 138 3 117 303 228 75...

Страница 21: ...er 21 Transmitter wall mount housing a0001150 Dimensions A B C D E F G H J 215 250 90 5 159 5 135 90 45 50 81 K L M N O P Q R S 53 95 53 102 81 5 11 5 192 8 M5 20 All dimensions in mm Esc E D C B A F...

Страница 22: ...the wall mounted housing It can be ordered from Endress Hauser as an accessory The following installation variants are possible Panel mounted installation Pipe mounting Panel mounted installation A00...

Страница 23: ...85 mm 82 50 80 8 x M16 x 225 mm 116 76 Diameter Pressure rating Mounting bolts Centering sleeve length Measuring tube internal diameter mm mm mm 25 JIS 10 K 4 x M16 x 170 mm 54 24 40 4 x M16 x 170 mm...

Страница 24: ...5 316L Ground disks 1 4301 304 Material load diagram Permitted process pressure a0010720 en Fitted electrodes Measuring electrodes x 2 made of 1 4435 316L Process connections EN 1092 1 DIN 2501 ANSI B...

Отзывы: