Description of device parameters
Proline Promag 300 Modbus RS485
164
Hauser
Assign SSID name
Navigation
Expert → Communication → WLAN settings → Assign SSID name (2708)
Description
Use this function to select which name is used for the SSID
.
Selection
• Device tag
• User-defined
Factory setting
User-defined
Additional information
Selection
• Device tag
The device tag name is used as the SSID.
• User-defined
A user-defined name is used as the SSID.
SSID name
Navigation
Expert → Communication → WLAN settings → SSID name (2707)
Prerequisite
• The
User-defined
option is selected in the
Assign SSID name
• The
Access point
option is selected in the
WLAN mode
Description
Use this function to enter a user-defined SSID name.
User entry
Max. 32-digit character string comprising numbers, letters and special characters
Factory setting
EH_device designation_last 7 digits of the serial number (e.g.
EH_Promag_300_A802000)
WLAN channel
Navigation
Expert → Communication → WLAN settings → WLAN channel (2704)
Description
Use this function to enter the WLAN channel.
User entry
1 to 11
Factory setting
6
Additional information
Description
• It is only necessary to enter a WLAN channel if multiple WLAN devices are in use.
• If just one measuring device is in use, it is recommended to keep the factory setting.
8)
Service Set Identifier