Flowmeter Proline 500 – digital
Electrical connection
Hauser
25
5.3.2
Connecting the signal cable and the supply voltage cable
1
2 3
4
5
6
A0028200
1
Terminal connection for supply voltage
2
Terminal connection for signal transmission, input/output
3
Terminal connection for signal transmission, input/output
4
Terminal connection for connecting cable between sensor and transmitter
5
Terminal connection for signal transmission, input/output; optional: connection for external WLAN
antenna
6
Protective earth (PE)
1.
3.
2.
4.
4 x
5.
7.
TX 20
TX 20
6.
10 (0.4)
22 mm
8.
24 mm
A0029597
1. Loosen the 4 fixing screws on the housing cover.
2. Open the housing cover.
3. Fold open the terminal cover.