NAR300 system for high temperature
Installation
Hauser
31
5.3.4
NRR261-3/5xx cable mounting
Mounting procedure
1. Remove the intrinsically safe terminal box cover [6] and the terminal block cover [5].
2. Insert the float sensor cable [2] into the cable gland [1] and cable entry of the
intrinsically safe terminal box.
3. Connect the cable to the terminal block (see "Electrical connection").
4. Tighten the main unit of cable gland [4] and the seal nut [3].
Tightening torque (main unit and seal nut): approx. 1.96 N·m (20 kgf cm)
5. Secure the cable in place with the cable holder.
6. Install the terminal block cover and close the intrinsically safe terminal box cover.
This completes the mounting procedure.
1
2
3
4
5
6
7
7
A0039883
19
NRR261-3xx cable mounting
1
Cable gland (supplied for TIIS/JPN Ex specifications only)
2
Float sensor cable
3
Seal nut
4
Cable gland main unit
5
Terminal block cover
6
Intrinsically safe terminal box cover
7
Cable gland (Ex d) (supplied for TIIS/JPN Ex specifications only)