Mounting
Micropilot M FMR 231 with HART/4...20 mA
18
E Hauser
3.4
Installation instructions
3.4.1
Mounting kit
In addition to the tool needed for flange mounting, you will require the following tool:
•
4 mm/0.1" Allen wrench for turning the housing.
3.4.2
Installation in tank (free space)
Optimum mounting position
L00-FMR231xx-17-00-00-en-001
Standard installation
For installations in a stilling well, follow the engineering hints on Page 14 and note the
following points:
•
Marker is aligned towards tank wall.
•
The marker is always exactly in the middle between two bolt-holes in the flange.
•
After mounting, the housing can be turned 350° in order to simplify access to the
display and the terminal compartment.
•
The inactive part of the rod antenna must extend below the nozzle.
•
The rod antenna must be aligned vertically.