Micropilot FMR62
Hauser
V. 4, Rev. 2, 19-03-2018
67
Industry Canada
Canada CNR-Gen Section 7.1.3
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) This device may not interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
[Any] changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
• The installation of the LPR/TLPR device shall be done by trained installers, in strict compliance
with the manufacturer’s instructions.
• The use of this device is on a “no-interference, no-protection” basis. That is, the user shall accept
operations of high-powered radar in the same frequency band which may interfere with or
damage this device. However, devices found to interfere with primary licensing operations will be
required to be removed at the user’s expense.
• This device shall be installed and operated in a completely enclosed container to prevent RF
emissions, which can otherwise interfere with aeronautical navigation.
• The installer/user of this device shall ensure that it is at least 10 km from the Dominion
Astrophysical Radio Observatory (DRAO) near Penticton, British Columbia. The coordinates of the
DRAO are latitude 49°19ʹ15ʹʹ N and longitude 119°37ʹ12ʹʹ W. For devices not meeting this 10 km
separation (e.g., those in the Okanagan Valley, British Columbia,) the installer/user must
coordinate with, and obtain the written concurrence of, the Director of the DRAO before the
equipment can be installed or operated. The Director of the DRAO may be contacted at
250-497-2300 (tel.) or 250-497-2355 (fax). (Alternatively, the Manager, Regulatory Standards
Industry Canada, may be contacted.)
• The model FMR62T is a submodel of the FMR62 that fulfills the requirements for use as
TLPR (Tank Level Probe Radar).
• The Model FMR62L is a submodel of the FMR62. "L" indicates the unique option GF of the
feature 070 ("Antenna") that fullfills the requirements for use as LPR (Level Probe Radar).
CRN approval
Some device versions have CRN approval. Devices are CRN approved if the following two conditions
are met:
• The device has a CSA approval (product structure: feature 010 "Approval")
• The device has a CRN-approved process connection as per the following table:
Feature 100 in the product structure
Process connection
AFK
NPS 2" Cl.150, PTFE >316/316L
AGK
NPS 3" Cl.150, PTFE >316/316L
AHK
NPS 4" Cl.150, PTFE >316/316L
AJK
NPS 6" Cl.150, PTFE >316/316L
ATK
NPS 4" Cl.300, PTFE>316/316L
MRK
DIN11851 DN50 PN25 slotted nut, PTFE>316L
MTK
DIN11851 DN80 PN25 slotted nut, PTFE>316L
RGJ
Thread ANSI MNPT1-1/2, 316L
TDK
Tri-Clamp ISO2852 DN51 (2"), PTFE>316L