Turbidity and solids concentration measurement with sensor CUS 31, CUS 41
Display and measuring range
Sensor CUS 31 . . . . . . . . . . . .
0 ... 9999 FNU, 0 ... 3000 ppm, 0 ... 3 g/l, 0 ... 200%
Sensor CUS 41 . . . . . . . . . . . 0 ... 9999 FNU, 0 ... 9999 ppm, 0 ... 300 g/l, 0 ... 200%
Measured value resolution
Sensor CUS 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . auto range
Sensor CUS 41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . auto range
Measurement deviation
1)
, display
. . . . . . . . . . . . . . . . . . . . . . max. 0.5% of MR
Reproducibility
1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 0.2% of MR
TU signal input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . digital
TU signal output
Current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 / 4 ... 20 mA
Measurement deviation
. . . . . . . . . . . . . . . . . . . . . . . . . max. 0.75% of MR
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 500
Ω
Output range . . . . . . . . . . . . . . . adjustable,
∆
0.1 FNU,
∆
1g/l,
∆
0.1%,
∆
10 ppm
Temperature measurement
Temperature sensor
. . . . . . . . . . . . . . . . . . . . . . . . . . . NTC, 30 k
Ω
at 25 °C
Display range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –5.0 ... +70 °C
Measured value resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 °C
Measurement deviation
1)
, display
. . . . . . . . . . . . . . . . . . . . . . . . . 1.0% of MR
Temperature signal output (optional)
Current range . . . . . . . . . . . . . . . . . . . . . 0 / 4 ... 20 mA, galvanically separated
Measurement deviation
1)
. . . . . . . . . . . . . . . . . . . . . . . . . max. 1.25% of URV
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 500
Ω
Output range . . . . . . . . . . . . . . . . . . . . . .
adjustable,
∆
10 ...
∆
100% of URV
Limit contactor
Limit adjustment range . . . . . . . . 0 ... 9999 FNU, 0 ... 9999 ppm, 0 ... 300 g/l, 0 ... 200%
Switching hysteresis
. . . 0.00 ... 99.99 FNU, 0.00 ... 99.99 ppm, 0.0 ... 99.9 g/l, 0.0 ...99.9%
Pickup / dropout delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 ... 2000 s
Contact type (switchable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MIN / MAX