Liquicap M FMI52 HART
Mounting
Hauser
11
4.2
Probe with separate housing
A
L4 ≤ 6m (20")
-
-
B
L1
A0040473
5
Connection of the probe and separate housing
A
Explosive zone 1
B
Explosive zone 0
L1 Rope length: max 9.7 m (32 ft)
L4 Cable length: max. 6 m (20 ft)
The maximum cable length L4 and rope length L1 cannot exceed 10 m (33 ft).
The maximum cable length between the probe and separate housing is 6 m (20 ft). The
required cable length must be indicated in the ordering process of a Liquicap M with
separate housing.
If the cable connection has to be shortened or led through a wall, then it must be
separated from the process connection.
4.2.1
Extension heights: separate housing
The cable:
• has a minimum bending radius of r ≥ 100 mm (3.94 in)
• diameter ⌀ 10.5 mm (0.14 in)
• outer jacket made of silicone, notch resistance