Mounting
Liquicap M FMI52 HART
10
Hauser
A0040453
4
A probe with fully insulated inactive length for mounting nozzles
Shortening the rope
For information about the shortening kit, see Brief Operating Instructions KA061F/00.
Tensioning weight with tension
The end of the probe needs to be secured if the probe would otherwise touch the silo wall or
another part in the tank. This is what the internal thread in the probe weight is intended for.
The bracing can be conductive or insulating to the tank wall.
To avoid too high tensile load, the rope should be loose or guyed with a spring. The maximum
tensile load may not exceed 200 Nm (147.5 lbf ft).
A0040462