background image

Mounting

Levelflex FMP53 PROFIBUS PA

16

Hauser

6.2.4  

Turning the display module

+

E

1

3 mm

1.

2.

3.

4.

  A0032238

1. If present: Loosen the screw of the securing clamp of the electronics compartment cover

using an Allen screw and turn the clamp 90° counterclockwise.

2. Unscrew cover of the electronics compartment from the transmitter housing.
3. Pull out the display module with a gentle rotational movement.
4. Rotate the display module to the desired position: max. 8 × 45° in each direction.
5. Feed the coiled cable into the gap between the housing and main electronics module

and plug the display module into the electronics compartment until it engages.

6. Screw the electronics compartment cover back onto the transmitter housing.
7. Tighten the securing clamp with an Allen screw (torque: 2.5 Nm).

Содержание Levelflex FMP53 PROFIBUS PA

Страница 1: ...ions they are not a substitute for the Operating Instructions pertaining to the device Detailed information about the device can be found in the Operating Instructions and the other documentation Avai...

Страница 2: ...Levelflex FMP53 PROFIBUS PA 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Страница 3: ...nditions 11 5 2 Transport product to the measuring point 11 6 Mounting 12 6 1 Mounting requirements 12 6 2 Mounting the device 13 6 3 Post installation check 17 7 Electrical connection 18 7 1 Connecti...

Страница 4: ...on on procedures and other facts which do not result in personal injury 1 1 2 Electrical symbols Symbol Meaning Symbol Meaning Direct current Alternating current Direct current and alternating current...

Страница 5: ...on A Reference to page Reference to graphic 1 2 3 Series of steps Result of a step Visual inspection 1 1 5 Symbols in graphics Symbol Meaning 1 2 3 Item numbers 1 2 3 Series of steps A B C Views A A B...

Страница 6: ...llowing measurements only Measured process variables level Calculated process variables Volume or mass in arbitrarily shaped vessels calculated from the level by the linearization functionality To ens...

Страница 7: ...ed operational safety and reliability Carry out repairs on the device only if they are expressly permitted Observe federal national regulations pertaining to repair of an electrical device Use origina...

Страница 8: ...ing of the device by affixing to it the CE mark 2 5 2 EAC conformity The measuring system meets the legal requirements of the applicable EAC guidelines These are listed in the corresponding EAC Declar...

Страница 9: ...ons XA present If one of these conditions is not satisfied contact your Endress Hauser Sales Center 4 2 Product identification The following options are available for identification of the measuring d...

Страница 10: ...order code Ext ord cd 4 2 D matrix code QR code For detailed information about interpreting the nameplate specifications refer to the Operating Instructions for the device Only 33 digits of the exten...

Страница 11: ...be damaged or break away Risk of injury Transport the measuring device to the measuring point in its original packaging or at the process connection Do not fasten lifting devices hoisting slings lift...

Страница 12: ...g distances Distance A between wall and rod probe for smooth metallic walls 50 mm 2 in for plastic walls 300 mm 12 in to metallic parts outside the vessel Distance B between rod probe and internal fit...

Страница 13: ...tronics housing The connection cable is fixed to the probe on delivery The probe with connection cable and the electronics are adjusted to match each other They are marked by a common serial number On...

Страница 14: ...B 42 60 1 65 2 36 A0014793 4 Mounting the electronics housing using the mounting bracket dimensions mm In A Wall mounting B Pipe mounting Connecting the cable Required tools For the coupling nut at t...

Страница 15: ...To provide easier access to the connection compartment or display module the transmitter housing can be turned max 350 8 mm 8 mm 1 2 3 A0032242 1 Unscrew the securing screw using an open ended wrench...

Страница 16: ...onics compartment from the transmitter housing 3 Pull out the display module with a gentle rotational movement 4 Rotate the display module to the desired position max 8 45 in each direction 5 Feed the...

Страница 17: ...or example Process temperature Process pressure refer to the chapter on Material load curves of the Technical Information document Ambient temperature range Measuring range m Are the measuring point i...

Страница 18: ...L D B U S Spare part 71023457 PA FF 06 07 FIELDBUS 1 3 2 4 P A F F 1 0 m m Spare part 71108xxx 2 wire level 4 20 mA PFS FIELDBUS 26 27 open A 4 1 1 2 3 6 5 3 3 4 4 A0011341 5 Terminal assignment PROF...

Страница 19: ...Levelflex FMP53 PROFIBUS PA Electrical connection Endress Hauser 19 4 Terminal for potential equalization line 5 Cable entries 6 Overvoltage protection module...

Страница 20: ...ieldbus plug connector M12 or 7 8 the signal line can be connected without opening the housing Pin assignment of the M12 plug connector 2 1 3 4 A0011175 Pin Meaning 1 Signal 2 not connected 3 Signal 4...

Страница 21: ...g to IEC 60079 27 Yes 7 1 4 Overvoltage protection If the measuring device is used for level measurement in flammable liquids which requires the use of overvoltage protection according to DIN EN 60079...

Страница 22: ...able national standards Comply with the specifications in the Safety Instructions XA Use specified cable glands only Check to ensure that the power supply matches the information on the nameplate Swit...

Страница 23: ...fit ferrules 6 Firmly tighten the cable glands 7 A0032468 Connect the cable in accordance with the terminal assignment 18 8 If using shielded cables Connect the cable shield to the ground terminal 9 F...

Страница 24: ...le undamaged visual check Do the cables comply with the requirements Do the cables have adequate strain relief Are all cable glands installed securely tightened and leak tight Does the supply voltage...

Страница 25: ...under www endress com www profibus org GSD file version 8 2 Set device address 2 9 8 3 4 5 6 7 8 1 D IP O N A0015686 8 Address switches in terminal compartment 8 2 1 Hardware adressing 1 Set switch 8...

Страница 26: ...o 7 define the address 8 2 2 Software addressing 1 Set switch 8 to ON 2 The device restarts automatically The address remains the same as before factory setting 126 3 Set the required address via the...

Страница 27: ...ssioning button calls up the wizard 3 Click on Commissioning to call up the wizard 4 Enter or select the appropriate value for each parameter These values are immediately written to the device 5 Click...

Страница 28: ...containing tag and error symbol if an error is active 1 2 Measured value symbols 1 3 Measured value 1 4 Unit 2 Measured value display 1 bargraph 1 value 2 1 Bargraph for measured value 1 2 2 Measured...

Страница 29: ...ing the key for 2 s for parameter If present opens the help text for the function of the parameter For text and numeric editor Pressing the key briefly Opens the selected group Carries out the selecte...

Страница 30: ...urve Keylock on Opening and closing the context menu The user is in the operational display 1 Press for 2 s The context menu opens XXXXXXXXXX kg h 50 Setup Conf backup disp Env curve Keylock on A00331...

Страница 31: ...ecial measuring conditions to process the measured value scaling linearization to configure the signal output Diagnostics Contains the most important parameters needed to detect and analyze operationa...

Страница 32: ...tions of the device BA01007F FMP53 PROFIBUS PA 10 4 Setting the operating language Factory setting English or ordered local language XXXX XXX X X 20 50 Operation Setup Main menu 0104 1 Display languag...

Страница 33: ...Level F Full calibration span 1 Setup Device tag Enter tag for measuring point 2 Setup Device address Enter bus address of the device only in case of software addressing 3 Setup Distance unit Select...

Страница 34: ...e level L 11 Setup Signal quality Displays the signal quality of the level echo 12 Setup Mapping Confirm distance Compare the displayed distance to the real distance in order to start the recording of...

Страница 35: ......

Страница 36: ...www addresses endress com 71385714 71385714...

Отзывы: