Deltapilot S
18
Hauser
Increased security
during parameter entry via
operating tool
For a description of the safety-related parameters
20 ff, "Parameter description of the SAFETY CONFIRM.
group" section.
This configuration method is a software function implemented in the device and comprising automated
parameter confirmation and device locking.
11, process diagram.
1.
Configure device.
→
Operating Instructions BA332P and BA274P.
Observe "Conditions for safe measuring mode" section,
2.
Note the settings of the following parameters since these settings are queried for safe device configuration:
3.
Select the "SAFETY CONFIRM." group. (Menu path: OPERATING MENU
→
SAFETY CONFIRM.).
4.
Select the "Lock" option via the SAFETY LOCK parameter. The SAFETY LOCKSTATE parameter displays
the status "Unlocked".
5.
Enter the password via the SAFETY PASSWORD parameter (password: 7452).
– If the password entered is correct, the following parameters are reset to the factory settings:
CURR. CHARACT., OUTPUT FAIL MODE, ALT. CURR. OUTPUT, SET MAX. ALARM,
SET MIN. CURRENT, SIMULATION, ALARM DELAY and ALARM DISPLAY TIME
(
→
Point 7 for factory values.)
– Any simulation running is terminated.
– The configurable messages ("Error"-type messages) 115, 120, 620, 715, 716, 717, 718, 720, 726 and
727 are set to "Alarm".
→
Operating Instructions BA332P, Section 8.1 "Messages".
– All the parameters to be confirmed are displayed.
6.
By means of the DIGIT SETS parameter, the user checks whether the characters and digits are displayed
correctly on the user interface. "0123456789.-" is displayed if everything is displayed correctly.
Options:
– Valid: Select this option if the string of characters and digits is displayed correctly.
– Not valid: Select this option if the string of characters and digits is not displayed correctly. In this case,
operation in the safe measuring mode is not possible.
Parameters
Available in the operating mode
Group
Pressure
Level,
"Level Easy Pressure"
level selection
ACK. ALARM MODE
X
X
MESSAGES
CALIB. OFFSET
X
X
POSITION ADJUSTMENT
MEASURING MODE
X
X
BASIC SETUP
PRESSURE EMPTY
X
BASIC SETUP
EMPTY CALIBRATION
X
BASIC SETUP
PRESSURE FULL
X
BASIC SETUP
FULL CALIBRATION
X
BASIC SETUP
SET LRV
X
X
BASIC SETUP
SET URV
X
X
BASIC SETUP
DAMPING VALUE
X
X
BASIC SETUP
!
Note!
The PRESSURE EMPTY and PRESSURE FULL parameters are only displayed for the "Dry" CALIBRATION MODE.
If you have performed a wet calibration, you subsequently have to select the "Dry" option by means of the
CALIBRATION MODE parameter. You can read out the corresponding values for the PRESSURE EMPTY and
PRESSURE FULL parameters here.
Содержание Deltapilot S FMB70
Страница 30: ...Deltapilot S 30 Endress Hauser Management summary Management_summary exida_2 Management_summary exida_1 ...
Страница 31: ...Deltapilot S Endress Hauser 31 Management_summary exida_3 ...
Страница 32: ...Deltapilot S 32 Endress Hauser Certificate TUEV_en ...
Страница 33: ...Deltapilot S Endress Hauser 33 ...