10. Turn control knob to (high) (Figure 5). Main burner will light immediately. Flame should
be visible through viewing hole. If not, turn control knob “ OFF,” wait 5 minutes, and
repeat lighting procedure.
11. If for some reason your igniter fails to deliver a spark, your heater can be started by
inserting a lit match through the pilot viewing hole while pushing the control knob in while
in the (pilot) position.
W
WARNING: Be careful when attempting to manually ignite this heater.
Holding in the control knob for more than 10 seconds before igniting
the gas will cause a ball of flame upon ignition.
W
CAUTION: If burner flame goes out during operation, immediately turn
the control knob to the “ OFF” position, LP gas tank valve “CLOSED”
and let the gas clear for 5 minutes before re-lighting.
TIP:
The burner may be noisy when initially turned on. To eliminate excessive noise from the
burner turn the control knob to the (pilot) position, then turn the knob to the level of heat
desired.
When Heater is On
W
WARNING: Dome and burner are extremely hot to the touch during
operation. Never touch the dome or burner while the heater is
operating. The surface of heater’s emitter can reach temperatures
approaching 1600ºF.
W
WARNING: Do NOT touch metal parts of heater until they have
completely cooled to avoid burns, unless you are wearing protective
gear (pot holders, gloves, BBQ mittens, etc.).
• Emitter screen will become bright red due to intense heat. The color is more visible at
night.
• Burner will display tongues of blue and yellow flame. These flames should not be yellow or
produce thick black smoke, indicating an obstruction of airflow through the burners. The
flame should be blue with straight yellow tops (Figure 7).
• If excessive yellow flame is detected, turn off heater and visit BlueRhino.com for cleaning
instructions or call 1.800.762.1142.
W
CAUTION: If burner flame goes out during operation, immediately turn
the control knob to the “ OFF” position, LP gas tank valve “CLOSED”
and let the gas clear for 5 minutes before re-lighting.
Re-lighting
Note: For your safety, the control knob cannot be turned the the “ OFF” position without first
depressing control knob in (pilot) position and then rotating it to “ OFF.”
1. Turn control knob to “ OFF.”
2. Wait at least 5 minutes to let gas dissipate.
3. Repeat the “Lighting” procedure.
Turning Off
1. Turn control knob clockwise to the (pilot) position. Burner will extinguish but pilot will
remain “ON.”
2. Turn LP gas tank valve to “CLOSED.”
Note: A “poof” sound is normal as the last of the LP gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
Note: After use, some discoloration of the emitter screen is normal.
Cleaning and Care
W
CAUTION:
1. All cleaning and maintenance should be done when heater is cool
and with the fuel supply disconnected.
2. Do NOT clean any heater part in a self-cleaning oven. The extreme
heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the
valves or burners.
Notices
1. This heater should be thoroughly cleaned on a regular basis.
2. Abrasive cleaners will damage this product.
3. Never use oven cleaner to clean any part of heater.
4. More frequent cleaning may be required as necessary. It is imperative that control
compartment, burners and circulating air passageways of the heater be kept clean.
5. Have heater inspected annually and repairs should be made by a qualified service
person.
6. Inspect heater before each use.
7. Spiders and insects can create a dangerous condition that may damage the heater
or make it unsafe. Keep burner area clean of all spiders, webs and insects. Clean
burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear
away smaller particles.
Operating Instructions
Checking for Leaks
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three parts
water.
2. Make sure control knobs are in the “ OFF”
position (Figure 3).
3. Connect LP gas tank per “Installing LP Gas Tank”
section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt
bottle, at all “X” locations (Figures 1 and 2).
a. If any bubbles appear, turn LP gas tank valve to
“CLOSED,” reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank, per “Disconnecting
LP Gas Tank” section. Contact 1.800.762.1142
for assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to “CLOSED,” wipe away
solution and proceed.
Before Lighting
First Use
1. Make sure all labels, packaging and protective
films have been removed from the heater.
2. Remove manufacturing oils on this heater for the
first time by operating the heater for at least 15
minutes on (HIGH). This will “heat clean” the
internal parts and dissipate odors.
Before Every Use
1. Inspected thoroughly before each use, and by a
qualified service person at least annually.
2. If relighting a hot heater, always wait at least
5 minutes.
3. Inspect the hose assembly for evidence of
excessive abrasion, cuts or wear.
a. Suspected areas should be leak tested.
b. If the hose leaks, it must be replaced prior to
operation.
c. Only use the replacement hose assembly
specified by manufacturer.
Lighting
This heater is equipped with a pilot light that allows for
safer startups and shutdowns. Pilot must be lit before
main burner can be started.
1. Check for obstructions of airflow to the burners.
Spiders, insects and webs can clog the burner/
venturi tube. A clogged burner tube can lead to
a fire.
2. Control knob must be in the “ OFF” position
(Figure 3).
3. Connect LP gas tank per “Installing LP Gas Tank”
section.
4. Turn LP gas tank valve to “OPEN.”
5. Open viewing hole by sliding cover to either side
(Figure 6).
6. Push control knob in and rotate to (pilot)
position (Figure 4).
Note: For initial start or after any tank change,
hold control knob in for 2 minutes to purge air
from gas lines before proceeding. Then wait 5
minutes before lighting heater.
7. Immediately push (igniter) button for five (5)
seconds. Pilot light flame will appear and be
visible through viewing hole (Figure 6).
8. Release control knob after 30 seconds. Pilot light
will remain lit.
9. If ignition does not occur, turn control knob to
“ OFF,” wait 5 minutes and repeat lighting
procedure.
Figure 1
Figure 2
X
X
X
X
X
Figure 3
OFF /
ARRÊT
Figure 4
OFF /
ARRÊT
Figure 5
OFF /
ARRÊT
Figure 6
Viewing Hole
Figure 7
Burner
Flame
Slight
Yellow
Slight
Blue
Dark
Blue
Содержание ES4000COMM
Страница 12: ...Outdoor LP Gas Heater Model No ES4000COMMM 12 ...