P5/8/08
Page 20 of 26
5.
Turn the circuit breaker to the Power Unit OFF. Fill the Power Unit with the 5 gallons
of hydraulic fluid provided.
NOTE: The fill cap is at the low-pressure fitting.
6.
Remove the oil filter by lifting it out of the fill opening. Once filled with oil, replace
the oil filter and cap and press firmly to ensure proper seating of the filter.
7.
If your hydraulic hose is a sufficient length to require additional fluid, it will be
included with the hydraulic run hose. In this case, fill with the full five gallons first
and run the Power Unit for one minute to fill the hydraulic run hoses. Turn Power
Unit off and add the additional oil.
NOTE: Do not run the Power Unit without
the fill cap in place.
8.
Be sure to bond the Fastlane Pool and the hydraulic Power Unit by connecting a #8
or larger copper bonding wire to the bonding lug located
??????
and running that
wire (typically along with the hydraulic hoses) back to the hydraulic Power Unit. Any
other piece of pool equipment with a bonding lug should also be bonded to the same
loop as the Fastlane Pool and the hydraulic Power Unit.
DIAGRAM #5: POWER UNIT ELECTRICAL WIRING