ENDEVCO 4830B Скачать руководство пользователя страница 2

IM4830B Rev B 

 

 

October 9, 2019 

SAFETY CONSIDERATIONS 

 

This equipment has been designed and tested in accordance with the following standards: 
EN61326-1:2006 

 

Electrical equipment for measurement, control and laboratory use – Group1, Class A 

 

 

 

 

 

(Emissions) 

EN61326-1:2006 

 

Electrical equipment for measurement, control and laboratory use – Industrial Location    

 

 

 

 

Immunity 

EN61000-3-2:2006 

 

Electromagnetic compatibility (EMC) – Part 3-2  

   (+A1/A2)   
EN61000-3-3:2008 

 

Electromagnetic compatibility (EMC) – Part 3-3  

CFR 47, Class A 

 

Code of Federal Regulations: Pt 15, Subpart B 

 
The 4830B has been tested as an Unintentional radiator (sub part B) and as a Class A product 
 
RADIO AND TELEVISION INTERFERENCE 
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the 
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to 
correct the interference at his own expense. 
 
In order to maintain compliance with FCC regulations shielded cables must be used with this equipment.   
Operation with non-approved equipment or unshielded cables is likely to result in interference to radio & television reception. 
 
This equipment is not designed to be used in potentially explosive environments.  It should not be used in the presence of 
flammable liquids or gases. 
This manual contains information and warnings that must be followed to ensure safety of personnel and the safe operation of the 
equipment. 
 
Warnings: 
Switch off all power to equipment before connecting or disconnecting the digital interface.  Failure to do so may cause damage to 
the equipment. 
Any adjustment, maintenance or repair, other than detailed within this manual, must be carried out by trained service personnel. 
If it is suspected that the correct operation of the equipment is threatened, impaired or otherwise, it must be made safe and free 
from further operation until the threat has been removed. 
 
Rohs Compliant 

 

2011/65/EU 

 
Waste Electronic and Electronic Equipment Directive: 2012/19/EU 
This product complies with the WEEE Directive (2012/19/EU) marking requirement.  The affixed product label (below) indicates that 
you must not dispose this electrical/electronic product in domestic household waste. 
 
To return unwanted product for disposal, please contact your local MSS representative. 

 

 

 

Содержание 4830B

Страница 1: ...IM4830B Rev B October 9 2019 4830B AccelerometerSimulator IM4830B Instruction manual ...

Страница 2: ...hich case the user will be required to correct the interference at his own expense In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio television reception This equipment is not designed to be used in potentially explosive environments It should ...

Страница 3: ...d must not be misrepresented as being the original software TERM OF LICENSE This LICENSE shall continue for as long as the USER uses the SOFTWARE and or distributes the SOFTWARE according to the terms of this agreement However this LICENSE will terminate if the USER fails to comply with any of its terms or conditions The limitations of warranties and liability set forth in this LICENSE shall conti...

Страница 4: ...nfiguration 11 3 5 3 Output socket select 11 3 5 4 Download data 11 3 5 5 About 11 3 6 Power 12 3 6 1 Low battery indicator 12 3 6 2 Battery charge indicator 12 3 7 Output types and typical connection configurations 12 4 0 Detailed operation 14 4 1 Parameter editing 14 4 2 Calculated parameters 14 4 2 1 Relationships 14 4 2 2 Back calculation 14 4 2 3 Display Format 15 4 3 Creating and saving a us...

Страница 5: ...5 1 2 Preliminary instructions 22 5 1 3 Procedure 22 5 2 Maintenance 23 5 3 Repair 24 6 0 Utility software 24 6 1 Introduction 24 6 2 Installing the utility software 24 6 3 Opening and running the utility 25 6 3 1 Creating and saving profiles profile sets 26 6 3 2 Editing a profile 27 6 3 3 Opening a profile set 29 6 3 4 Saving a profile set 29 6 3 5 Adding a profile 29 6 3 6 Delete last profile 2...

Страница 6: ...lacement An auto calculating on screen Vibration Calculator provides the user with corresponding values in respect of m s ips mils mm and m s based units The instrument also features a TTL compatible tachometer output which allows operators of condition monitoring systems to set signal conditioning tracking filter center frequencies without the need to generate an external real time tachometer sig...

Страница 7: ...IM4830B Rev B 7 October 9 2019 2 0 User interface Figure 1 4830B user interface ...

Страница 8: ... lower When the simulator is turned on the upper screen becomes the default This screen shows the Profile in use and an overview of the four primary simulation parameters The secondary parameters are shown in the lower screen Moving between the upper and lower screens is accomplished by pressing the up and down arrow keys Pressing the HOME menu key at any point will return the display to the home ...

Страница 9: ...r 3 4 The Profile A Profile is a set of parameters that combine to form the simulation Parameters include Signal frequency Freq Accelerometer sensitivity Sens Acceleration level g Waveform type Type Acceleration level m s2 Velocity ips Displacement mils Displacement mm Velocity m s Ratio In terms of simulating an accelerometer the primary parameters are sensitivity acceleration level g frequency a...

Страница 10: ...ault profile a user profile can be edited and saved on the fly See section 4 3for details on creating a User profile Note Downloading a new profile set will erase any user profiles saved within the simulator 3 4 3 Profile selection Profile selection is accessed by pressing the PROFILESmenu key Scroll up or down with the arrow keys to move between profiles and select the profile required by pressin...

Страница 11: ... to gain access to the calibration process For security and to avoid inadvertent calibration the password should remain with authorized personnel See section 5 1for the calibration procedure 3 5 2 4 Firmware upgrade Should it be necessary to upgrade the firmware at any stage the process will be initiatedwithin this routine Full details on how to install the upgrade will be providedat the time a fi...

Страница 12: ... trickle charge mode the indicator will be a solid green for approximately 45 minutes A red indication means a fault has been detected 3 7 Output types and typical connection configurations The simulator provides AC output signals that mimic those of charge mode piezoelectric PE accelerometers both single ended and differential configurations and voltage mode piezoelectric accelerometers often ref...

Страница 13: ...IM4830B Rev B 13 October 9 2019 Examples of typical connection configurations for the 4830B are shown in Figure 11 Figure 11 Typical connection configurations ...

Страница 14: ...value cannot be saved Figure 13 Out of range message The waveform Type uses only the up and down arrow keys for editing Select from sinusoidal triangular or square wave by using these keys 4 2 Calculated parameters 4 2 1 Relationships Whenever the values of freq or g level are changed the secondary parameters are automatically recalculated The secondary parameters i e ips m s mils and mm are calcu...

Страница 15: ...ome screen Figure 15 Format edit screen 4 3 Creating and saving a user profile User profiles can be created and saved into internal memory using the key pad A maximum of 40 user profiles can be saved within internal memory for quick and easy retrieval To create a user profile use the following procedure which assumes that only the default profile is present Starting from the home screen press the ...

Страница 16: ...u It should be noted that this function will clear all of the user profiles stored within memory Note It is not possible to remove individual profiles using this function Profile removal all using the front panel keypad is performed as follows From the home screen press the TOOLSmenu key Using the down arrow key step through the menu until CONFIGURATION is highlighted Press the ENTER key Again usi...

Страница 17: ...Hz and 0 50 kHz Use the left and right arrow keys to move between ranges An indication of the selected bandwidth is shown in the top right of the display The FFT function automatically picks the fundamental and this is shown in the top left of the display Note If the fundamental is measured as being below 5 Hz it will be shown as 5Hz on the display Figure 20 FFT screen Amplitude range is limited t...

Страница 18: ...IM4830B Rev B 18 October 9 2019 ...

Страница 19: ...n the configuration menu step through the menu until the word Backlight Menu is highlighted Press the ENTER key The Backlight Menu screen is now displayed Figure 22 Backlight menu screen Use the up and down arrow keys to switch between backlight ON and backlight OFF Press the ENTER key to save the setting The display will now return to the home screen The backlight can also be toggled on or off by...

Страница 20: ...Use the up and down keys to change the configuration Press the ENTER key to save and exit to the home screen 4 12 Master reset The simulator can be reset from the key pad should it be necessary To perform the reset simultaneously press the up and left arrow keys The display will go blank and then reinitialize Performing a master reset will not affect the default or user profiles stored within memo...

Страница 21: ...current and constant voltage modes and charges the battery to approximately 85 of its capacity in approximately 3 hours In this mode the charge indicator will be flashing green Once 85 capacity has been achieved the charging will automatically switch into Stage 2 ...

Страница 22: ...e unit A single adjustment made using the key pad is all that is required to perform the calibration The calibration function is password protected to ensure that unauthorized or inadvertent changes cannot be made Following a successful calibration the date is automatically logged within the internal memory and available to view in the ABOUT screen The calibration password is located on the rear o...

Страница 23: ...M reading should be within the range 70 00 to 71 41 mV rms Measurement 2 Change the g level setting to 1000 0 The DMM reading should be within the range 7 000 to 7 141 V rms If the values measured are not within the ranges stated then repeat the Adjustment 1 step setting the output to a level whereby the values measured and recorded in Measurements 1 and 2 come within range Note the value set in t...

Страница 24: ...t specific profiles within a profile set for download Generate a customized description for each profile This replaces the automatic User Profile X name allocated when a profile is created locally on the simulator Create a note against each profile the profile note is only visible in the utility software View the input limitations of each parameter reference the Fixed Outer limits field The utilit...

Страница 25: ...xe insert version number into the search window in the start menu and press return If using Windows 7 locate the 4830B SimulatorUtility Setup Vxxx application file on the CD DVD drive using windows explorer Double click on the file to start the installation A drop down menu will appear Double click on Run as administrator The software installation process will now begin Follow the prompts provided...

Страница 26: ...t can be seen that the profile name waveform type profile notes and the parameters change from profile to profile 6 3 1 Creating and saving profiles profile sets The utility installer will create a Profile Sets folder in the directory C Program Files Utility Profile Manager Unless otherwise directed profile sets will be stored in this directory A profile cannot be created and saved singularly it h...

Страница 27: ...ply click on the profile name in the list Fields are then accessed either by the keyboard Tab Key or by clicking on to them using the mouse button 6 3 2 1 Editing a profile name Enter the new name for the profile into the Profile Name box keeping it to a maximum of 17 characters in length Pressing the Update Profile button will change the profile name in the list Once downloaded to the simulator t...

Страница 28: ...ibration parameters are calculated values and will change whenever the frequency or g level values are edited refer to paragraph 4 2 1 for details of the relationships Similarly the tacho Hz value is non editable and will change whenever the ratio tacho value is changed The secondary parameters can themselves be edited as described above and whenever a change in value is made the value of g will c...

Страница 29: ...with the same default parameters values 6 3 5 Adding a profile To add a profile to an existing profile set right click with the mouse on the profile list A new profile will be added to the end 6 3 6 Delete last profile Select from the pull down menu above the profile list Delete Last Profile A confirmation message will be displayed click OK to delete the last profile 6 3 7 Communicating with the s...

Страница 30: ...ulator will show the message Data Received Safely The selected profiles are now stored in the simulator s internal memory and can be viewed and loaded in the profiles menu 6 3 7 2 Clock synchronization The simulator real time clock can be synchronized with the host PC clock This is best achieved at the same time when profiles are to be downloaded Otherwise connect the simulator to the host PC usin...

Страница 31: ...Included EHM2107 Universal power supply supplied with adaptors for USA UK EURO JAPAN and Australia Included EHM2108 Soft carrying case with cable pouch and shoulder strap Included EW1400 USB interface cable mini B to USB Included 43664 XXX Differential Cable Assembly Adaptor 2 Pin 7 27 17 to Twinax BNC XXX defines cable length Optional 43655 XXX Triaxial Cable Assembly Adaptor Female 4 pin to 3x m...

Страница 32: ...der to set the correct operating bias i e as an accelerometer would do Connecting to multiple IEPE signal conditioner inputs is not a practice that should be undertaken as damage to the unit and or the signal conditioner may occur The connection of a single IEPE type accelerometer to multiple signal conditioners is not something that would be done in practice The mV and Tach outputs are a single e...

Отзывы: