Pre-Operation
Transportation and Storage Requirements
The Slam Stick is an electronic device and therefore its performance, especially battery life, can
be severely impacted by the environment it is transported and/or stored in. Midé recommends
that the Slam Stick be both transported and stored at room temperature, 20 to 25°C (68 to 77°F).
It is also recommended that the transportation and/or storage environment have a low, <50%,
relative humidity (RH).
CAUTION:
Be sure to transport and/or store the device in an environment that does not
expose it to water, fuel, oil, wet paint or other liquids and contaminants that could
damage the Slam Stick.
Although Midé recommends transportation/storage at room temperature with low humidity, the
Slam Stick has been tested in accordance with MIL-STD-810G to ensure survival at extreme
temperatures. This testing included exposure to -40°C for eight hours and 80°C for eight hours
without loss of performance. Extreme humidity testing was also completed which included
exposure to an environment of 60°C and 95% RH, non-condensing, for eight hours.
CAUTION:
Although the data logger has been tested and proven to survive short
durations of extreme environmental conditions, prolonged exposure can drastically
reduce battery life and cause the device to be out of calibration.
If the Slam Stick will not be used for an extended period of time, it is recommended to recharge
the device at least twice per year to prevent over discharge. More frequent recharging may be
required if stored at high temperatures.
NOTE: