background image

Page 14

BANDIT III Reference Module, Document 1

Go to 

Table of 

Contents

Go to 

Top 

Doc

Go to 

List of 

All Docs

1.2.2

Protocol Status LEDs

In addition to indicating general status, each port’s Activity LED indicates conditions for the 
protocol configured on that port. 

Table 1-7

 describes the LEDs for protocols the BANDIT 

supports. 

Modem 
Carrier Detect/
Activity 

Twentieth 

Green 

Connection has been made to carrier. 

Off 

Connection to carrier has failed. 

Green flashing 

Data is being transmitted or received. 

Module Link

5

Top row, first 
from left 

Green 

Connection has been made. 

Off Connection 

has 

failed. 

Module 
Activity

5

Top row, 
second from 
left

Green flashing 

Data is being transmitted between the 
Internal Data Unit (IDU) ports and the 
BANDIT III base system (the lower row 
of ports). 

Link for IDU 
Port 1

5

Top row, third 
from left

Green 

Connection has been made to carrier. 

Off 

Connection to carrier has failed. 

Link for IDU 
Port 2

5

Top row, 
fourth from left

Green 

Connection has been made to carrier. 

Off 

Connection to carrier has failed. 

Link for IDU 
Port 3

5

Top row, fifth 
from left

Green 

Connection has been made to carrier. 

Off 

Connection to carrier has failed. 

Link for IDU 
Port 4

5

Top row, sixth 
from left

Green 

Connection has been made to carrier. 

Off 

Connection to carrier has failed. 

1. LEDs are on the base (bottom) row unless otherwise indicated. 
2. This LED functions only for the BANDIT’s expansion-port cards. 
3. This LED functions only for the dual T1/E1 CSU/DSU port. 
4. If the transmit and receive pairs are accidentally reversed at the service provider’s connector, the WAN 
port’s Activity LED stays on (not flashing). This is because the reversed connection reverses the sealing 
current and sends the unit into test mode (i.e., analog loopback). 
5. This LED is only for a BANDIT III chassis with an Internal Data Unit (IDU). 

Table 1-7. BANDIT III Protocol Status LED Definitions

 (Sheet 1 of 2)

Protocol

Green Activity LED 

Frame Relay

If a Frame Relay Management protocol connection is up, the 
LED lights after 15–20 seconds. (If there is no connection, the 
Activity LED remains unlit.) 

Async Encapsulation

Characters, bidirectional TD/RD 

Bit Sync Encapsulation

Frames in either direction 

Table 1-6. BANDIT III General Status LED Definitions

 (Sheet 3 of 3)

LED 

Location 
(from left 
side)

1

 

Color 

Description 

Top Doc

Doc List

Module TOC

Содержание BANDIT III

Страница 1: ...ally hardened chassis with a metal cover Hardened construction allows the BANDIT III to operate over wide temperature ranges at remote sites that do not use environmental control The BANDIT III like a...

Страница 2: ...T III Chassis with Ethernet Switch Module Expanded BANDIT III Chassis with Internal Data Unit BANDIT III E M Signaling Chassis 1 1 1 Standard BANDIT III Chassis The basic BANDIT III chassis Figure 1 2...

Страница 3: ...24 48 volts DC input power Figure 1 5 or for 12 24 volts DC input power Figure 1 6 When you order a BANDIT III you specify the type of input power it will use Note Each DC powered BANDIT III chassis a...

Страница 4: ...nd 110 220 VAC Input Power Figure 1 6 BANDIT III Chassis Rear Panel Basic Model 12 24 VDC Input Power or Failover 12 24 VDC and 110 220 VAC Input Power The following items are on the back of the basic...

Страница 5: ...or X 21 56k CSU DSU port T1 E1 CSU DSU port Dual port T1 E1 CSU DSU port with drop and insert capability A second wireless card this can be the same type CDMA EVDO CDMA GPRS GSM or EDGE GSM as the in...

Страница 6: ...a Unit As stated earlier the BANDIT III is also available in an expanded model with an Internal Data Unit IDU comprising four DB25 serial ports for additional VPN functionality The expanded BANDIT III...

Страница 7: ...igurations for the BANDIT III chassis Two failover input power configurations 24 48 VDC with 110 220 VAC or 12 24 VDC with 110 220 VAC Each BANDIT III chassis that uses DC input power basic Figure 1 4...

Страница 8: ...III is available in models that accept power from a DC power source at 24 48 VDC or 12 24 VDC or in models that accept power from an industry standard autosensing 100 240 VAC adapter connected to an A...

Страница 9: ...connections to network devices Section 1 1 9 1 Ethernet Ports Section 1 1 9 2 Modem Port Section 1 1 9 3 Serial Port Section 1 1 9 4 Wireless Ports Also see Section 1 1 10 Expansion Ports Note The BA...

Страница 10: ...tp SNMP MIB II ARP Proxy ARP Routing over VPN tunnels 1 1 9 2 Modem Port An internal modem resides in the BANDIT III Connect the modem port to an RJ11 telephone jack 1 1 9 3 Serial Port The BANDIT III...

Страница 11: ...ion ports available in the BANDIT III see Ports in the BANDIT Products If the expansion port is for a wireless connection also see Wireless Cards for BANDIT Products 1 2 Status LEDs Light emitting dio...

Страница 12: ...4 indicates that the connection is up between that serial port and its connected device Table 1 6 describes the BANDIT III s LEDs Table 1 6 BANDIT III General Status LED Definitions Sheet 1 of 3 LED...

Страница 13: ...in a set is equivalent to the same number of bars displaying signal strength on a mobile phone Flashes display in one of the following patterns A set of short flashes followed by a longer final flash...

Страница 14: ...ow fifth from left Green Connection has been made to carrier Off Connection to carrier has failed Link for IDU Port 45 Top row sixth from left Green Connection has been made to carrier Off Connection...

Страница 15: ...G Good frames are passing through Byte Sync Encapsulation Good frames are passing through X 25 Level II connection exists Telnet Terminal Data transfer in either direction 1 When using spoofed protoco...

Страница 16: ...Page 16 BANDIT III Reference Module Document 1 Go to Table of Contents Go to Top Doc Go to List of All Docs Top Doc Doc List Module TOC...

Отзывы: