ENCO Control
Technical description
•
Kulautuvos g. 45a , LT-47190 Kaunas
•
Tel. (+370 37) 360234
•
Faks. (+370 37) 360358
•
•
www.axis.lt
10
2.3. DHCP settings
1. DHCP Off
2. IP 10.2.3.207
3. GW 10.2.3.254
4. MK 255.255.255.0
Field
Description
1. DHCP
On/Off
2. IP
device IP address
3. GW
gateway IP address
4. MK
network mask
Ping settings with Remote Server via LAN:
2.4. Ping settings
1. Ping Off
2. Ping gateway On
3. Ping period 1440
4. IP 0.0.0.0
Field
Description
1. Ping
On/Off
2. Ping gateway
On / Off
3. Ping period
Ping period
4. IP
Remote server's IP address, if Ping does not take place with gateway
Setting time synchronization of device via network:
2.5. NTP settings
1. Check time Off
2. NTP interface Ethr
3. NTP period 1440
4. NTP port 123
5. IP 192.168.0.1
6. Time zone +2
Field
Description
1. Check time
Time synchronization On/Off
2. NTP interface
Communication interface to synchronize the time
3. NTP period
Time synchronization period
4. NTP port
Number of port of synchronization server
5 IP
IP address of synchronization server
6. Time zone
Select time zone
Automatic
changes over to daylight saving time (On/Off)
:
2.6. Summer correct.
1. Off
2. On
activate (deactivate) the
automatic
summer / winter time.
Select reboot device (On/Off):