Users’ Manual
EAN-26MH Horizontal inclinometer system
Page
|
11
2.15
Form loop at the end of pull cable with the adjustable clamp. Tighten the set screws after
adjusting the cable length. The excess free cable length protruding out of the clamp can be cut
off with a steel wire cutter.
2.16
The length of the pull cable can be adjusted (shortened) to the desired length by loosening the
set screws and drawing out the free end of the pull cable through the adjustable clamp.
2.17
Connect the pull cable loop to protective cap (Refer to figure 10). The removable pin of the
protective cap is unscrewed from one end. The loop of the pull cable is then guided over the end
of the pin and the pin is screwed back to the cap to anchor the pull cable. Figure 9 shows how
the loop of the pull cable at the cable reel end is fixed to the protective cap. This pull cable loop
has to be removed from the protective cap and fixed to the pull cable reel for reeling when taking
readings.
2.18
The other end of the pull cable has a threaded adaptor for fixing the protective cap. The threaded
adaptor should be kept engaged to the casing end cap as shown in Figure 11 when not in use.
Figure 9 Loop for fixing
Figure 10 Pull cable at reel end fixed to the protective cap
Loop for anchoring
in protective cap
Pull cable
Protective cap
Adjustable cable clamp
Pull cable reel end
ABS Casing
Removable
Pin
Set screws
Adjustable clamp