background image

I

NSTALLING

 T

HE

 865W PRO G

IGABIT

 P

O

E E

XTENDER

 

he Enable-IT 865W PRO Gigabit PoE Extenders have a distance reach of up to 3,000ft (915m) 

over any 1-pair wiring (Telephone, Coax, or Category rated) between the 865W PRO units. You 

can add additional 328ft (100m) onto the end of each 865W PRO LAN output ports for a total 

distance of 3,000ft (915m) from device extension to device extension.   Therefore a site survey 

of the wiring and installation planning are highly recommended.   For highest performance use 

lower gauge wiring like 14AWG ~ 24AWG for the interlink wiring. 

We highly recommend that you perform a quick out of the box test to ensure the working order of your 

Enable-IT 865W PRO Gigabit PoE Extender units prior to installing.  This will also serve to familiarize 

you with how easy the process should be. Follow the steps below to perform the Out Of the Box Test.

 

 

Step 1 

- Attach the 865W PRO 60W 56V PoE injector to the 865W PRO CO unit and to your AC outlet.   

              The Power LED will indicate the 865W PRO CO unit is receiving power. 

 

Step 2

 - Connect the 865W PRO units together using one of the Ethernet LAN Patch cords provided – attach  

  

  to the RJ-45 Interlink port on each 865W PRO unit as shown by the green line connecting the  

 

 (Interlink) ports in the diagram above.  The 865W PRO CO unit will have a solid Link LED when  

             connected to the Extender unit successfully. 

Step 3 

- Attach and test and to confirm your PoE Equipment works through the 865W PRO extension, connect   

  

  your Ethernet LAN to the 865W PRO Injector unit LAN port and the remote device/s to the 865W PRO  

              Extender LAN port and test connectivity.   

 

 This confirms basic proper operation of the units.

Performing the On-Site Installation 

After  removing  the  Enable-IT  865W  PRO  Gigabit  PoE  Extender  Kit  from  the  box,  and 

performing the Out Of The Box Testing (OOTBT), all that remains to install the unit on-site is to 

mount  the  unit,  build  the  interconnect  wiring,  add  voice  lines  if  needed,  and  attach  the  LAN 

device cabling with the provided Ethernet Patch cords. 

Mounting the Enable-IT 865W PRO Gigabit PoE Extender Units 

The  Enable-IT  865W  PRO  extended  Ethernet  solution  is  designed  for  quick  wall  mounting.  

Choose a location to mount each of the Enable-IT 865W PRO’s where the maximum distance 

does not exceed 

3,000ft (915m)

 total between devices to be connected.    When wall-mounting 

the Enable-IT 865W PRO unit it is recommended that you use the appropriate screw anchors 

for your mounting surface.  If mounting on existing plywood use wood screws; if mounting onto 

drywall or sheetrock, use plastic drywall anchors to secure your installation. 

 

 

All Rights Reserved © 1997 - 2019   Enable-IT

, Inc.                                                                               Page   of 