EMX Industries, Inc.
Tech support: 216-518-9889
2/3
HAWK 2_Rev2.0_062420 [email protected]
Wiring
Wire Color
Description
Red
12-24 VDC/AC
Black
12-24 VDC/AC
Green
Relay
–
COM (common contact)
Brown or Yellow
Relay
–
NO (normally open contact)
Blue
Relay
–
NC (normally closed contact)
Diagram & Settings
1.
Output Period Setting
The output period setting allows for
adjustment of the output duration
contact after motion is no longer
detected. The output period can be set
to 1 to 6 seconds. Rotating the setting
clockwise increases the output period.
Rotating the setting counterclockwise
decreases the output period.
2.
Range Setting
After DIP switch 4 is set to a high or low
sensitivity, the range setting can be
used to fine tune the detection area.
3.
DIP Switches
Detection Mode
DIP Switch 1
In
Bi-Directional
mode the relay is activated when motion occurs
both leaving and approaching the sensor, DIP switch 2 is ignored.
In
Mono-Directional
mode the relay is activated only when
motion occurs in the direction specified by DIP switch 2.
Bi-Directional
on
Mono-Directional
off
Mono-Directional
Mode
DIP Switch 2
DIP switch 2 determines which direction of motion activates the
relay when in Mono-Directional mode.
Detect Leaving
on
Detect Approaching
off
Configures the relay contacts position (NO/NC) when in detect
and no-detect states.
Normal Operation
Positive Safety
Relay Operation
DIP Switch 3
Normal Operation
on
Positive Safety
off