background image

 

EMX Industries, Inc. 

Tech support: 216-518-9889 

2/3

 

HAWK 2_Rev2.0_062420                                     [email protected]

 

 

Wiring  

 

Wire Color 

Description 

Red 

12-24 VDC/AC 

Black 

12-24 VDC/AC 

Green 

Relay 

 COM (common contact) 

Brown or Yellow 

Relay 

 NO (normally open contact) 

Blue 

Relay 

 NC (normally closed contact) 

 

Diagram & Settings 

 

1.

 

Output Period Setting 

The output period setting allows for 
adjustment of the output duration 
contact after motion is no longer 
detected. The output period can be set 
to 1 to 6 seconds. Rotating the setting 
clockwise increases the output period. 
Rotating the setting counterclockwise 
decreases the output period.  

 

2.

 

Range Setting 

After DIP switch 4 is set to a high or low 
sensitivity, the range setting can be 
used to fine tune the detection area.  

 

3.

 

DIP Switches 

 

Detection Mode 

DIP Switch 1 

In 

Bi-Directional

 mode the relay is activated when motion occurs 

both leaving and approaching the sensor, DIP switch 2 is ignored. 
In 

Mono-Directional

 mode the relay is activated only when 

motion occurs in the direction specified by DIP switch 2.  

Bi-Directional 

on 

Mono-Directional 

off 

 

Mono-Directional 
Mode 

DIP Switch 2 

DIP switch 2 determines which direction of motion activates the 
relay when in Mono-Directional mode.  

Detect Leaving  

on 

Detect Approaching 

off 

 

Configures the relay contacts position (NO/NC) when in detect  
and no-detect states. 

 

 

 

 

         Normal Operation 

Positive Safety 

Relay Operation 

DIP Switch 3 

Normal Operation  

on 

Positive Safety 

off 

Отзывы: