EMX Industries, Inc.
Tech support: 216-518-9889
3/3
HAWK 2_Rev2.0_062420 [email protected]
Sensitivity
Adjustment
DIP Switch 4
DIP switch 4
determines the area of
detection. The primary
purpose of the
sensitivity setting is to
allow the installer the
ability to control the
area of detection.
Low
on
High
off
Installation
1.
Wire the HAWK 2 according to the Wiring section and according to operator instructions.
2.
Remove the rubber plug from the back of the sensor and configure the DIP switches,
output period, and range as desired.
3.
Mount the HAWK 2 at a height between 10-20 feet. Use the provided mounting template to drill
appropriately distanced holes on the mounting surface.
Do not install the Hawk 2:
•
Facing the moving parts of a door
•
Facing and closer than 6.5 feet to fluorescent lights
•
Facing an area where rain could provoke water fluxes
4.
Remove the lower cover of the mounting base and loosen the screw that locks the sensor
orientation using a size 3 allen key. Aim the HAWK 2 towards the desired detection area and lock
the screw in that position. Replace the lower cover of the mounting base and rubber plug.
5.
Test the setup by causing motion in the detection zone and adjust the Range Setting until the
desired detection is achieved. The red LED will be on when the motion in the configured
direction(s) is detected.
Red LED
No Detection
Off
Detection
On
6.
Cease movement and the red LED will turn off once the output period has passed.
Warranty
EMX Industries, Inc. products have a warranty against defects in materials and workmanship for a period
of two years from date of sale to our customer.
TIP: