background image

 
CS101 Operating Instructions 

 

Document no.

  10070104 

 

 

 

Cautions and Warnings 

 

 

Never  use  the  CS101™  as  a  safety  reversing  or  presence  detection  system.  
The CS101™ requires that a vehicle be moving for detection. This product is 
an accessory or part of a system. Always read and follow the manufacturer’s 
instructions  of  the equipment  before connecting  this product.    Comply  with 
all  applicable  codes  and  safety  regulations.    Failure  to  do  so  may  result  in 
damage, injury or death. 

 

 

DO NOT INSTALL PROBE IN HOT ASPHALT 

 

 

PROVIDE  AN  EARTH  GROUND  CONNECTION  USING  GROUND  ROD  PER 
INSTALLATION INSTRUCTIONS

 

 

 

DO NOT EXCEED POWER SUPPLY VOLTAGE RATING 41VDC or 29VAC 

 

 

ALLOW 5 MINUTES AFTER POWER UP FOR STABILIZATION 

 

 

CS101  is  sensitive  to  metal  objects  that  move  through  its  field,  including 
bicycles,  horses,  small vehicles  or  metal  in  shoes.    Reduce  the  sensitivity  as 
required  to  eliminate  detection.      In  areas  with  high  pedestrian  traffic,  the 
probe may be buried up to 24” deep to prevent triggering the detector by the 
metal in shoes.  

 

 

 

Product Overview

 

  

The CS101™ is a compact vehicle motion detector that operates by detecting changes in the earth’s 
magnetic field that occur near the probe.  These changes are produced by the movement of ferrous 
materials  such  as  cars  or  trucks  within  the  probe’s  range.    The  CS101  uses  the  CS101  series  direct 
burial probes placed adjacent to a roadway or buried in a concrete or asphalt roadway.   
 
The probe features a 12ft. detection range that is dependent on the speed and size of the vehicle. The 
probe is available in a wide variety of cable lengths. 
 
The CS101 features adjustable sensitivity and output “on” time.  A green LED is indicates that power is 
applied to the unit while a red LED indicates detection.  The output consists of form C relay contacts 
(N.O, N.C., C).   
 
The  CS101  may  be  used  as  a  free  exit  sensor  in  both  commercial  and  residential  applications.   

The detector is not for use as a presence detector.

  When presence detection is needed, use the EMX 

D-TEK series detectors and inductive loop. 

 

 

Содержание CarSense 101

Страница 1: ...I O N S Operating Instructions 4564 Johnston Parkway Cleveland Ohio 44128 P 800 426 9912 F 216 518 9884 Sales Inquiries salessupport emxinc com Technical Support technical emxinc com www emxinc com Ca...

Страница 2: ...nstructions 1 Document no 10070104 Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Operation 4 Controls and Indicators 4 Connections 5 Troubleshooting 6 Loop Installation 7 Orderi...

Страница 3: ...ian traffic the probe may be buried up to 24 deep to prevent triggering the detector by the metal in shoes Product Overview The CS101 is a compact vehicle motion detector that operates by detecting ch...

Страница 4: ...n Form C SPDT Relay contact rating 1A 24VDC 1A 120VAC Detect indicator Red LED Power indicator Green LED Power 9 41VDC or 6 29VAC and 110 VAC Model Standby current 2 5mA Detection current 50mA Operati...

Страница 5: ...nt panel indicates that power is applied to the unit and should always be on The red LED on the front panel indicates detection and the activation of the output relay The sensitivity adjustment allows...

Страница 6: ...contact 4 RELAY 1 Common relay common contact 5 RELAY 1 N C relay normally closed contact 6 Probe shield wire Earth ground provides connection for transient and noise suppression devices reference EAR...

Страница 7: ...ng a separate power supply for the CS101 such as a 120VAC to 12V power converter min 100ma Re connect the probe and test the system 4 If the false triggering continues inspect the area around the prob...

Страница 8: ...stallation If it is necessary to extend the cable length use a high quality lead in cable suitable for direct burial and a high quality watertight cable splice to prevent moisture from entering the ca...

Страница 9: ...stment detection distance is approximately 12ft at a speed of 5mph At higher speeds 10 15mph detection distance can exceed 12ft 1 Prior to permanent installation adjacent to the roadway place the prob...

Страница 10: ...cut may be made in the pavement for installation No rebar should be above the probe 2 Once the probe is installed connect the probe to the CS101 and power output contact and earth ground to the inten...

Страница 11: ...lack 11 pin DIN rail mount 1 included LD 11 Socket base gray 11 pin DIN rail mount HAR 11 Connector 11 pin free hanging with 36 wire harness 240 56857 Power convertor 110VAC to 12VDC PROBE 50 CS 101 d...

Страница 12: ...e or use other than intended design There is no warranty of merchantability There are no warranties expressed or implied or any affirmation of fact or representation except as set forth herein EMX Ind...

Страница 13: ...CS101 Operating Instructions 12 Document no 10070104 BLANK PAGE...

Страница 14: ...CS101 Operating Instructions 13 Document no 10070104 BLANK PAGE...

Страница 15: ...ument no 10070104 4564 Johnston Parkway Cleveland Ohio 44128 United States of America www emxinc com Technical Support 216 834 0761 technical emxinc com Sales 216 518 9888 Fax 216 518 9884 salessuppor...

Отзывы: