11.

 

How to LOCK / UNLOCK the system  

The unit can be LOCKED, so that none of users can use the system and activate the relay.  
To lock the system, send SMS: 

*9999 Is the password (default password 9999)   

 9999lock  

To unlock the system, send SMS:   

 9999unlock  

The unit will reply by SMS accordingly: 

The unit is LOCKED 

The unit is UNLOCKED 

12.

 

HOLD Command    

The HOLD COMMAND enables you to overtake control of the system and keep the relay of the 
unit active (ON) until cancellation command is received. When the unit’s relay is in HOLD mode, 
the unit will not respond to any other command until a cancellation command is received.  
 
When the HOLD COMMAND is active ON, the unit will send SMS to each user that calls to trigger 
the gate to open saying: 

 Hold Command is Active  

To activate the Hold Command send SMS as follows: 

*9999 Is the password (default password 9999)   

9999hold   

The unit will reply by SMS:  

 Hold Command is ON 

To cancel the Hold Command send SMS as follows:  

 9999release   

The unit will reply by SMS:  

 Hold Command is OFF 

 
 
 

Содержание CellOpener-365

Страница 1: ...Timer and 365 Day Timer capability to offer maximum security and allow a property manager to prevent a gate or overhead door from opening on certain days and times such as national holidays or specia...

Страница 2: ...ite and Blue wires are the internal relay s connections Normally Open N O Com You can select Normally Close N C contact instead of the N O contact of the internal relay by the external jumper in the u...

Страница 3: ...d Note There is no need for the dot at the end of the SMS command The maximum phone numbers are 5 phone numbers that can be added or deleted by one SMS command The unit should reply by SMS that says C...

Страница 4: ...of how to allow an unlimited number of entries within a specific timeframe and on certain days of the week for a special user with the phone number 041 831 7452 9999AS 0418317452 0 0900 1700 127 9999...

Страница 5: ...17 Access limited to Saturdays and Sundays The unit should reply by SMS saying Confirming The number 0418317435 is allowed 3 entries at any time on Sundays and Saturdays Note Please insert 0000 0000 f...

Страница 6: ...conds up to 99 seconds Use the following commands to set the pulse time 9999 Is the password default password 9999 9999pulse00 for a second pulse time 9999pulse01 for 1 second pulse time Factory Defau...

Страница 7: ...the unit checks the caller s ID the mobile phone number of each incoming call and registers it automatically in the system s memory and at the same time triggers the relay according to the chosen set...

Страница 8: ...MAND enables you to overtake control of the system and keep the relay of the unit active ON until cancellation command is received When the unit s relay is in HOLD mode the unit will not respond to an...

Страница 9: ...he unit will reply by SMS Open To All is OFF 14 How to Set the Unit to Factory Default Settings To set the unit to Factory Default Settings means the unit will delete all the phone numbers and reset a...

Страница 10: ...hat means the GATE is CLOSED and if it is not connected to ground open circuit it means the gate is OPEN To check the status of this input send SMS command as follows 9999 Is the password default pass...

Страница 11: ...r this input is The gate was opened You can program the phone number and different messages by sending SMS message as follows 9999AL Phone number _ _ _ Message max 25 characters _ _ _ The following is...

Страница 12: ...will turn OFF the relay 17 00PM 127 Representing the days of the week Sunday Monday and Saturday you must put a comma before the next command 0800 The starting time is 08 00AM 1300 The stopping Time i...

Страница 13: ...800 0900 23456 0800 1700 17 Second SMS 9999WT2 1500 1600 23456 The unit will confirm by sending SMS with the settings registered in the system Note When the unit s relay is ON active by the weekly tim...