3.
How to clear the settings of Weekly Timer:
Send SMS:
9999WT.clear
The unit will delete the current settings of the weekly timer and reply by SMS message as
follows:
No events are recorded for the Weekly Timer
Yearly Timer
The Yearly Timer can be programmed to overtake control of the weekly timer and turn ON or
OFF the relay output on certain days at certain times. For example:
To turn OFF the relay on 1st of September 2020 from 7:00AM until 13:00PM the next day.
This feature is very useful for setting public holidays and special events without the need of
accessing the unit on site.
*Note: This unit will automatically adjust the local time when daylight saving is due.
1.
How to set the Yearly Timer
The following SMS message is an example of how to set the yearly timer:
9999YT.010920.0700.020920.1300.OFF
9999
The default password 9999
YT
setting the Yearly Timer
010920
DDMMYY starting date: 1st Sep. 2020
0700
The time that the Yearly Timer will take control over the weekly timer is to be
07:00AM
020920
DDMMYY Ending date: 2nd Sep. 2020
1300
The time when the yearly timer finishes taking control over the weekly timer
is 13:00PM
OFF
The yearly timer will take control of the weekly timer and set the relay to OFF
during the above days and time interval.
The unit will reply by SMS that says:
Confirming: Yearly Timer OFF: 01.09.20, from 07:00AM until 02.09.20 24:00PM
Another example:
9999YT.050119.0000.050119.2400.ON