![EMTRION emCON-MX8MM Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/emtrion/emcon-mx8mm/emcon-mx8mm_hardware-manual_2404992016.webp)
emCON-MX8MM - Hardware Manual (Rev1)
16/33
POWER_ON_BASE:
During some power down states, the 3.3V areas of the CPU module will be switched off. In this case
all the peripheral chips which are connected to 3.3V referenced signals have to be switched off,
too. Otherwise the CPU will be back-powered via the I/O pins.
The signal POWER_ON_BASE can be used to control a DC/DC converter or a mosfet to switch the
3.3V on the baseboard on and off. Example schematics are available.
POWERFAIL#
The signal POWERFAIL# is an input to signalize a power fail condition. A low will trigger an
interrupt, e.g. to safe data.
ON_OFF# & WAKEUP:
The signals ON-OFF# and Wakeup are used to control the PMIC so it gets up from power down
states.
BAT:
The emCON BAT pin is the battery input pin for the RTC power supply. The typical power
consumption of the RTC via the BAT pin is < 1µA.
4.21.2
Power Consumption
A benchmark document [3] from NXP provides measurements and detailed information about the
power consumption of the i.MX8MM processor itself.