EM TEST
AN 200
Bedienungsanleitung
V 2.00
10 / 16
4.
Technical Data
Test supply
AN 200
AN 200B
Voltage range
0-30 VDC
0-60 VDC
Rated current
25 A
50 A
Short circuit protected
max. inrush current
> 500 A
Peak voltage capability
1000 V
Overvoltage protection
by varistors
Electronic switch
Switching time (test load L=7 µH / R=0.6
Ω
) 300 - 400 ns
Switch-off time can be selected
10 ms / 200 ms
Artificial network
Impedance according ISO/DIN 7637
5 µH - 50
Ω
Inductance
(5 µH / 5 m
Ω
)
Shunt resistor (Rs)
Internal selectable
40
Ω
/ 10
Ω
Option:
External shunt resistor (Rs = 2
Ω
)
2
Ω
Trigger
MANUAL
Manual trigger of a single event
AUTO
Automatic trigger with 1Hz
EXT
External trigger 0V, BNC
Mode
NORMAL
Switch and artificial network are activated
SWITCH
Only the switch is activated
ARTIFICIAL NETWORK
Only the network is activated
Measurement
Trigger output for CRO
BNC, positive edge + 15 V
Measuring probe included
BNC, 1 : 100
±
2%
Switch-on indication
LED-display
Dimensions (L x B x H)
AN 200
AN 200B
425 x 530 x 180 mm
425 x 530 x 360 mm
19“ 3HE
19“ 6HE
Weight
10 Kg
28 kg