The AN 200 is used to evaluate automotive electrical and
electronic components for conducted emissions of transients
along battery fed or switched supply lines of a Device Under
Test (DUT). A device under test which is considered a potential
source of conducted disturbances should be tested according to
ISO 7637 part 2.
The AN 200 includes an electronic switch for repeatable
switching of  inductive loads as well as an artificial network as
specified in ISO.

  ISO 7637 Part 2

Version:  2.00 / 21.11.2003

emc test  equipment

Replaces: 1.00 / 24.11. 1997

Filename: AN200x operating manual V200.doc

Printdate: 21.11.03

Содержание AN 200

Страница 1: ...y lines of a Device Under Test DUT A device under test which is considered a potential source of conducted disturbances should be tested according to ISO 7637 part 2 The AN 200 includes an electronic...

Страница 2: ...rk 9 4 Technical Data 10 5 Calibration Measuring procedure 11 5 1 Test load 11 5 2 Test voltage 11 5 3 Switch off times 11 5 4 Blockdiagram 11 5 5 Measuring results 12 5 5 1 Voltage drop in dependence...

Страница 3: ...r conducted emission transients ISO 7637 Teil 2 Road vehicles Electrical disturbances by conduction and cpouling Part 2 Electrical transients conduction along supply lines only several standards In ac...

Страница 4: ...g the ARTIFICIAL NETWORK button the artificial network is put into operation The electronic battery supply switch is short circuited The AN 200 can be used as an artificial network only 4 TEST ON By p...

Страница 5: ...stor value of 2 The 2 value is required when measuring transient emissions as per ISO DIN 7637 standard 10 Selection of the shunt resistor With this knob the shunt resistor can be switched to 40 10 or...

Страница 6: ...for the DUT is connected to this input The nominal dc supply parameters allowed are 30V 25A 4 Measuring output with 50 coaxial resistor For measuring conducted emission spectrum on battery supply lin...

Страница 7: ...r are in the circuit For remove the RC network you must disconnect the 50 Resistor Rz at the rear side of the AN 200 Figure 4 Switch The switch inside the AN 200 is active and the inductance is bypass...

Страница 8: ...1000V The electronic switch are electronically protected against overload and can withstand short circuit conditions Specific protection requirements of the EUT must be separately assured by the user...

Страница 9: ...cal network Inductance L 5 H Rl 5m RC Network Cz 0 1 F 250V ac Rz 50 Source input Connectors A B Output DUT Connectors P B Figure 8 The parallel resistor Rz 50 is built as a coaxial resistor and is pl...

Страница 10: ...ding ISO DIN 7637 5 H 50 Inductance 5 H 5 m Shunt resistor Rs Internal selectable 40 10 Option External shunt resistor Rs 2 2 Trigger MANUAL Manual trigger of a single event AUTO Automatic trigger wit...

Страница 11: ...off times should be determined under varying test voltages Proposals for Va U1 13 5V and U2 27V Consequently constant currents of 22 5A or 45A must be considered Due to the fact that the AN 200 is onl...

Страница 12: ...to standards All measuring values indicated as well as the curve illustrated have been recorded with a serial model Reference values measured with AN 200 Input Voltage 17 75 V Output Voltage 13 50 V U...

Страница 13: ...nvironment and operator Please refer to the safety manual before starting to work with the AN 200 Figure 15 Setup for pulses in the ms range Figure 16 Setup for pulses in the s ns range Important The...

Страница 14: ...ery Groups 7 1 Basic equipment Artifical network AN 200 AN 200B Mains cable 1 set safety labor cables red black Manual on CD Calibration certificate 7 2 Options AN 200B Artifical network for 60V 50A F...

Страница 15: ...s to which conformity is declared Emissions EN 61000 6 4 2001 EN 55022 1998 A1 2000 Class A EN 61000 3 2 A14 2000 Conducted and radiated Harmonics Immunity EN 61000 6 2 2001 EN 61000 4 2 1995 A1 1998...

Страница 16: ...EM TEST AN 200 Bedienungsanleitung V 2 00 16 16 8 2 AN 200 Overview Figure 19 Overview AN 200 AN 200B...

Отзывы: