RFID Interface
50
LRP820S-Series Long-Range Passive Reader/Writers
Example
The goal is to write ASCII 'A' (41H) to the ten bytes of tag memory
starting at byte address 5. A timeout of 2 seconds (07D0H = 2000 x 1
msec increments) is set for the completion of the command.
Command from Host
SuccessfulResponse From Controller
MSB LSB Remarks
AAH
04H
Command echo
AAH 04H Perform
Command 4
FFH
FFH
Message
Terminator
00H
05H Start Address =
0005H
00H
0AH Fill Length= 10
bytes(000AH)
07H
D0H Timeout value
00H
41H Data Value Byte =
41H
FFH
FFH Message
Terminator