Title
LRP2000 Long Range Passive Reader/Writer
9
3.2
Antenna Cabling
Figure 3-3. Antenna Connectors
Figure 3.3 shows the two antenna connectors at the base of the
LRP2000 antenna. Connect one end of the antenna cable assembly,
CBL-1475, to the antenna connectors at the base of the antenna.
Mate the connectors at the opposite end of the cable assembly to the
corresponding RF connector on the controller as shown in Figure 3.1.
The cable assembly has two different types of RF connectors, one
threaded TNC and one bayonet-syle BNC. The controller has one
TNC and seven BNC connectors. The BNC connector of the antenna
cable assembly must only be connected to the controller connector
shown in Figure 3.1.
CAUTION:
The antenna cables must be properly connected to both
the controller and the antenna at any time that power is
applied to the controller. Failure to properly connect the
controller to the antenna can cause damage to the unit.
Connecting the controller to any antenna other than the
LRP2000 Antenna can not only damage the controller, but
can void the operator's authority to operate the LRP2000.