Configuring the Menu
36
LRP2000 Long Range Passive Reader/Writer
DSP Program V0.5c, November 2002
*******************************************
[1] Set-up Operating Parameters
[2] Download Main Program
[3] Download DSP Program
[4] Exit to Operating Mode
Enter Selection:
5.2
Set-up Operating Parameters
To change the operating parameters of the LRP2000, enter 1 at the
initial menu. The following menu will be displayed, listing the current
settings. The exact appearance of the menu display will dependon the
settings you have made, and will be updated when you save your
changes.
Serial Port COM1: RS232, 9600, N, 8, 1, No handshake
(DIP switches)
Serial Port COM2: RS232, 9600, N, 8, 1, No handshake
Operating Mode: ABx Standard
RF Communication: Fast Mode
[1] Set COM1 Parameters
[2] Set COM2 Parameters
[3] Set Operating Mode
[4] Set RF Communications
[5] Restore Factory Defaults
[6] Return to Main Menu
Enter Selection: Enter the number of the sub-menu you wish to enter.
When you have made your selection you will be prompted to save
your changes to the non-volatile EEPROM. For the new settings to
take effect, you must save your changes to the EEPROM and reset
the LRP2000. If you do not save changes to the EEPROM, the new
settings will be effective only until the LRP2000 is reset. The following
sub-menus are presented here in their entirety. When operating, the
menus will be presented one option at time, advancing as you enter
selections. Some options shown are dependent on earlier selections.
Содержание LRP2000 Series
Страница 1: ...OPERATOR S MANUAL LRP2000 Series Passive Reader Writer Manual Revision 17 05 02 Publication 17 1257...
Страница 4: ......
Страница 11: ...Installation and Guidelines LRP2000 Long Range Passive Reader Writer 5 Figure 2 3 Antenna Bolt Pattern...
Страница 12: ...Installation and Guidelines 6 LRP2000 Long Range Passive Reader Writer...
Страница 40: ...Communications Interface 34 LRP2000 Long Range Passive Reader Writer...