busoff
bus off behavior
This key defines the period in milliseconds,
which shall be waited until the gateway gets
bus on again after a bus off condition has oc-
cured. If this value is not defined, the device
remains in bus off state. If a bus off time of 0
milliseconds is set, the gateway tries immedi-
ately to get bus on again.
Example :
busoff = 100
password
password
Using a password, the gateway can be protec-
ted against unauthorized access. If the key is
not defined or the value is set to 0, password
protection is disabled. The password is an up
to 14-digit hexadecimal value.
The password protection supports two security
levels.
For the highest security level the highest bit
(56th bit) of the password must be set to 1.
This security level prevents any communicati-
on with the gateway, if the device has not been
unlocked with the correct password before.
At the normal security level, the highest bit
(56th bit) is 0. Read out of information about
the gateway and the configuration is enabled.
Changing the configuration however is not
possible!
Example:
# Security: high
CG-ARM7/RMD
CAN/CAN - Gateway
User Manual
7